MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Peripartum management of patient with long QT3 after successful implantable cardioverter defibrillator device discharge resulting in device failure: a case report
Peripartum management of patient with long QT3 after successful implantable cardioverter defibrillator device discharge resulting in device failure: a case report
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Peripartum management of patient with long QT3 after successful implantable cardioverter defibrillator device discharge resulting in device failure: a case report
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Peripartum management of patient with long QT3 after successful implantable cardioverter defibrillator device discharge resulting in device failure: a case report
Peripartum management of patient with long QT3 after successful implantable cardioverter defibrillator device discharge resulting in device failure: a case report

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Peripartum management of patient with long QT3 after successful implantable cardioverter defibrillator device discharge resulting in device failure: a case report
Peripartum management of patient with long QT3 after successful implantable cardioverter defibrillator device discharge resulting in device failure: a case report
Journal Article

Peripartum management of patient with long QT3 after successful implantable cardioverter defibrillator device discharge resulting in device failure: a case report

2021
Request Book From Autostore and Choose the Collection Method
Overview
Abstract Background Long QT3 syndrome type 3 (LQT3) is a gain of function mutation of the SCN5A gene that is inherited in an autosomal dominant fashion. Long QT3 syndrome type 3 results in an increase in arrhythmic events during rest, sleep, and bradycardia by extending the QT interval and inducing Torsades de pointes and sudden cardiac death. Attempting to block the sodium channel with Class I anti-arrhythmics or blocking adrenergic tone with beta-blockers especially in women has shown to be beneficial. There have been few large-scale studies on treating patients with LQT3 due to its lethality and underreported number of cases. Specifically, the safety and efficacy of pharmacologic treatment in pregnant LQT3 patients are unknown. Case summary This case demonstrates the safe use of Mexiletine and Propranolol in a 3rd-trimester pregnant LQT3 patient after a presumed ventricular arrhythmia and device-lead electrical short from therapy rendered her implantable cardioverter defibrillator inoperable in a VVI mode (venticular demand pacing). With appropriate medications, the patient was safely monitored through the remainder of her pregnancy and safely delivered at 36 weeks of pregnancy a healthy baby girl. The daughter, heterozygous for LQT3, showed no evidence of intrauterine growth restriction or other side effects from the medications. Discussion There are many variants of the SCN5A gene mutations that can lead to different phenotypes and not all mutations are responsive to the same medications. In this case, Mexiletine and Propranolol, both of which have only recently shown to benefit certain variants or LQT3 respectively, were safely started during the 3rd trimester of pregnancy without harming the foetus.