Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Cost-effectiveness of Screening for Atrial Fibrillation Using Wearable Devices
by
McManus, David D.
, Ashburner, Jeffrey M.
, Khurshid, Shaan
, Chen, Wanyi
, Singer, Daniel E.
, Lubitz, Steven A.
, Ellinor, Patrick T.
, Chhatwal, Jagpreet
, Atlas, Steven J.
in
Aged
/ Anticoagulants
/ Atrial Fibrillation - diagnosis
/ Cardiac arrhythmia
/ Comments
/ Cost analysis
/ Cost-Benefit Analysis
/ Economics
/ Electrocardiography
/ Female
/ Health risks
/ Hemorrhage - complications
/ Humans
/ Male
/ Middle Aged
/ Online Only
/ Original Investigation
/ Stroke - diagnosis
/ Wearable computers
/ Wearable Electronic Devices
2022
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Cost-effectiveness of Screening for Atrial Fibrillation Using Wearable Devices
by
McManus, David D.
, Ashburner, Jeffrey M.
, Khurshid, Shaan
, Chen, Wanyi
, Singer, Daniel E.
, Lubitz, Steven A.
, Ellinor, Patrick T.
, Chhatwal, Jagpreet
, Atlas, Steven J.
in
Aged
/ Anticoagulants
/ Atrial Fibrillation - diagnosis
/ Cardiac arrhythmia
/ Comments
/ Cost analysis
/ Cost-Benefit Analysis
/ Economics
/ Electrocardiography
/ Female
/ Health risks
/ Hemorrhage - complications
/ Humans
/ Male
/ Middle Aged
/ Online Only
/ Original Investigation
/ Stroke - diagnosis
/ Wearable computers
/ Wearable Electronic Devices
2022
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Cost-effectiveness of Screening for Atrial Fibrillation Using Wearable Devices
by
McManus, David D.
, Ashburner, Jeffrey M.
, Khurshid, Shaan
, Chen, Wanyi
, Singer, Daniel E.
, Lubitz, Steven A.
, Ellinor, Patrick T.
, Chhatwal, Jagpreet
, Atlas, Steven J.
in
Aged
/ Anticoagulants
/ Atrial Fibrillation - diagnosis
/ Cardiac arrhythmia
/ Comments
/ Cost analysis
/ Cost-Benefit Analysis
/ Economics
/ Electrocardiography
/ Female
/ Health risks
/ Hemorrhage - complications
/ Humans
/ Male
/ Middle Aged
/ Online Only
/ Original Investigation
/ Stroke - diagnosis
/ Wearable computers
/ Wearable Electronic Devices
2022
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Cost-effectiveness of Screening for Atrial Fibrillation Using Wearable Devices
Journal Article
Cost-effectiveness of Screening for Atrial Fibrillation Using Wearable Devices
2022
Request Book From Autostore
and Choose the Collection Method
Overview
Undiagnosed atrial fibrillation (AF) is an important cause of stroke. Screening for AF using wrist-worn wearable devices may prevent strokes, but their cost-effectiveness is unknown.
To evaluate the cost-effectiveness of contemporary AF screening strategies, particularly wrist-worn wearable devices.
This economic evaluation used a microsimulation decision-analytic model and was conducted from September 8, 2020, to May 23, 2022, comprising 30 million simulated individuals with an age, sex, and comorbidity profile matching the US population aged 65 years or older.
Eight AF screening strategies, with 6 using wrist-worn wearable devices (watch or band photoplethysmography, with or without watch or band electrocardiography) and 2 using traditional modalities (ie, pulse palpation and 12-lead electrocardiogram) vs no screening.
The primary outcome was the incremental cost-effectiveness ratio, defined as US dollars per quality-adjusted life-year (QALY). Secondary measures included rates of stroke and major bleeding.
In the base case analysis of this model, the mean (SD) age was 72.5 (7.5) years, and 50% of the individuals were women. All 6 screening strategies using wrist-worn wearable devices were estimated to be more effective than no screening (range of QALYs gained vs no screening, 226-957 per 100 000 individuals) and were associated with greater relative benefit than screening using traditional modalities (range of QALYs gained vs no screening, -116 to 93 per 100 000 individuals). Compared with no screening, screening using wrist-worn wearable devices was associated with a reduction in stroke incidence by 20 to 23 per 100 000 person-years but an increase in major bleeding by 20 to 44 per 100 000 person-years. The overall preferred strategy was wearable photoplethysmography, followed conditionally by wearable electrocardiography with patch monitor confirmation, which had an incremental cost-effectiveness ratio of $57 894 per QALY, meeting the acceptability threshold of $100 000 per QALY. The cost-effectiveness of screening was consistent across multiple scenarios, including strata of sex, screening at earlier ages (eg, ≥50 years), and with variation in the association of anticoagulation with risk of stroke in the setting of screening-detected AF.
This economic evaluation of AF screening using a microsimulation decision-analytic model suggests that screening using wearable devices is cost-effective compared with either no screening or AF screening using traditional methods.