MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Dead-time compensation in three-phase grid-tied inverters using LQG multivariable control
Dead-time compensation in three-phase grid-tied inverters using LQG multivariable control
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Dead-time compensation in three-phase grid-tied inverters using LQG multivariable control
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Dead-time compensation in three-phase grid-tied inverters using LQG multivariable control
Dead-time compensation in three-phase grid-tied inverters using LQG multivariable control

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Dead-time compensation in three-phase grid-tied inverters using LQG multivariable control
Dead-time compensation in three-phase grid-tied inverters using LQG multivariable control
Journal Article

Dead-time compensation in three-phase grid-tied inverters using LQG multivariable control

2023
Request Book From Autostore and Choose the Collection Method
Overview
Dead-time is the most important disturbance in a voltage-source inverter’s operation. It introduces low-order harmonics at the inverter’s output voltage. To compensate for the dead-time effects in three-phase grid-tied inverters, this paper proposes a Linear Quadratic Gaussian (LQG) multivariable control approach. The LQG multivariable control is known as a robust control approach while provides a high band-width for the closed-loop system. Therefore, it promises significant attenuations in the dead-time introduced harmonics. To achieve a high performance, we run the three-phase grid-tied inverter in the current-controlled mode. Based on the nominal multivariable model derived for the three-phase grid-tied inverter in a synchronous reference frame, the LQG controller is composed such that the closed-loop system exhibits robust stability while attenuates disturbances significantly. The dead-time introduced harmonics produce disturbances in the synchronous reference frame with the highest frequencies. This is the reason for considering the dead-time as the most important disturbance in an inverter’s operation. For an experimental set-up manufactured for the three-phase grid-tied inverter, we developed a detailed model in MATLAB/Simulink. It is employed for the performance verifications of designed LQG controller. Extensive results are presented for different important scenarios, based on which, the excellent performance of proposed approach is proven. In fact, by employing the proposed approach, the dead-time introduced harmonics are significantly attenuated such that a Total Harmonics Distortions (THD) of about 5% is achieved for the injected currents to grid which meets the IEEE 1547 standard.