Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Constant false alarm rate detection of pipeline leakage based on acoustic sensors
by
Huang, Zuheng
, An, Guorui
, Li, Yanbing
in
639/166/4073
/ 639/166/987
/ Acoustics
/ False alarms
/ Humanities and Social Sciences
/ Leak detection
/ Leakage
/ multidisciplinary
/ Pipelines
/ Science
/ Science (multidisciplinary)
/ Signal processing
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Constant false alarm rate detection of pipeline leakage based on acoustic sensors
by
Huang, Zuheng
, An, Guorui
, Li, Yanbing
in
639/166/4073
/ 639/166/987
/ Acoustics
/ False alarms
/ Humanities and Social Sciences
/ Leak detection
/ Leakage
/ multidisciplinary
/ Pipelines
/ Science
/ Science (multidisciplinary)
/ Signal processing
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Constant false alarm rate detection of pipeline leakage based on acoustic sensors
by
Huang, Zuheng
, An, Guorui
, Li, Yanbing
in
639/166/4073
/ 639/166/987
/ Acoustics
/ False alarms
/ Humanities and Social Sciences
/ Leak detection
/ Leakage
/ multidisciplinary
/ Pipelines
/ Science
/ Science (multidisciplinary)
/ Signal processing
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Constant false alarm rate detection of pipeline leakage based on acoustic sensors
Journal Article
Constant false alarm rate detection of pipeline leakage based on acoustic sensors
2023
Request Book From Autostore
and Choose the Collection Method
Overview
During the transportation of oil and gas pipelines, there are many potential factors that can lead to pipeline leakage with serious consequences, making automatic and real-time pipeline leakage detection urgent. In response to the inconvenience of manual detection, constant false alarm rate (CFAR) detection technique in radar target detection theory is introduced for pipeline leakage detection based on acoustic signals. In this paper, an automatic pipeline leakage detection algorithm based on an improved CFAR detector is proposed. The improved CFAR detection is executed after pre-processing the acoustic signals so as to adaptively set the detection threshold to achieve the purpose of automatic detection of pipeline leakage incidents. A simulated leakage test of a real pipeline is used for validation, and the proposed method achieves detection accuracies of 84.6%, 97.7%, and 98% for different leakage diameter settings, i.e., 5 mm, 7 mm, and 10 mm leak hole diameters, respectively, with an overall accuracy of 94.1%, while the false alarm rates are 3.3%, 0.7%, and 0, respectively, as well as an overall of 1.2%. The results of experimental data based on real scenarios demonstrate the effectiveness of the proposed method.
Publisher
Nature Publishing Group UK,Nature Publishing Group,Nature Portfolio
This website uses cookies to ensure you get the best experience on our website.