Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Optical Surface Scanning for Patient Positioning in Radiation Therapy: A Prospective Analysis of 1902 Fractions
by
Niyazi, M
, Carl, G
, Alongi, F
, Pazos, M
, Corradini, S
, Reitz, D
, Freislederer, P
, Ganswindt, U
, Reiner, M
, Belka, C
, Schönecker, S
in
Abdomen
/ Adult
/ Aged
/ Aged, 80 and over
/ Cone-Beam Computed Tomography
/ Female
/ Humans
/ Lasers
/ Male
/ Middle Aged
/ Neoplasms - pathology
/ Neoplasms - radiotherapy
/ Original
/ Patient positioning
/ Patient Positioning - methods
/ Radiation therapy
/ Radiotherapy, Image-Guided - methods
/ Scanners
/ Workflow
2018
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Optical Surface Scanning for Patient Positioning in Radiation Therapy: A Prospective Analysis of 1902 Fractions
by
Niyazi, M
, Carl, G
, Alongi, F
, Pazos, M
, Corradini, S
, Reitz, D
, Freislederer, P
, Ganswindt, U
, Reiner, M
, Belka, C
, Schönecker, S
in
Abdomen
/ Adult
/ Aged
/ Aged, 80 and over
/ Cone-Beam Computed Tomography
/ Female
/ Humans
/ Lasers
/ Male
/ Middle Aged
/ Neoplasms - pathology
/ Neoplasms - radiotherapy
/ Original
/ Patient positioning
/ Patient Positioning - methods
/ Radiation therapy
/ Radiotherapy, Image-Guided - methods
/ Scanners
/ Workflow
2018
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Optical Surface Scanning for Patient Positioning in Radiation Therapy: A Prospective Analysis of 1902 Fractions
by
Niyazi, M
, Carl, G
, Alongi, F
, Pazos, M
, Corradini, S
, Reitz, D
, Freislederer, P
, Ganswindt, U
, Reiner, M
, Belka, C
, Schönecker, S
in
Abdomen
/ Adult
/ Aged
/ Aged, 80 and over
/ Cone-Beam Computed Tomography
/ Female
/ Humans
/ Lasers
/ Male
/ Middle Aged
/ Neoplasms - pathology
/ Neoplasms - radiotherapy
/ Original
/ Patient positioning
/ Patient Positioning - methods
/ Radiation therapy
/ Radiotherapy, Image-Guided - methods
/ Scanners
/ Workflow
2018
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Optical Surface Scanning for Patient Positioning in Radiation Therapy: A Prospective Analysis of 1902 Fractions
Journal Article
Optical Surface Scanning for Patient Positioning in Radiation Therapy: A Prospective Analysis of 1902 Fractions
2018
Request Book From Autostore
and Choose the Collection Method
Overview
Purpose/Objective:
Reproducible patient positioning remains one of the major challenges in modern radiation therapy. Recently, optical surface scanners have been introduced into clinical practice in addition to well-established positioning systems, such as room laser and skin marks. The aim of this prospective study was to evaluate setup errors of the optical surface scanner Catalyst HD (C-RAD AB) in different anatomic regions.
Material/Methods:
Between October 2016 and June 2017 a total of 1902 treatment sessions in 110 patients were evaluated. The workflow of this study included conventional setup procedures using laser-based positioning with skin marks and an additional registration of the 3-dimensional (3D) deviations detected by the Catalyst system. The deviations of the surface-based method were then compared to the corrections of cone beam computed tomography alignment which was considered as gold standard. A practical Catalyst setup error was calculated between the translational deviations of the surface scanner and the laser positioning. Two one-sided t tests for equivalence were used for statistical analysis.
Results:
Data analysis revealed total deviations of 0.09 mm ± 2.03 mm for the lateral axis, 0.07 mm ± 3.21 mm for the longitudinal axis, and 0.44 mm ± 3.08 mm vertical axis for the Catalyst system, compared to −0.06 ± 3.54 mm lateral, 0.53 ± 3.47 mm longitudinal, and 0.19 ± 3.49 mm vertical for the laser positioning compared to cone beam computed tomography. The lowest positional deviations were found in the cranial region, and larger deviations occurred in the thoracic and abdominal sites. A statistical comparison using 2 one-sided t tests showed a general concordance of the 2 methods (P ≤ 0.036), excluding the vertical direction of the abdominal region (P = 0.198).
Conclusion:
The optical surface scanner Catalyst HD is a reliable and feasible patient positioning system without any additional radiation exposure. From the head to the thoracic and abdominal region, a decrease in accuracy was observed within a comparable range for Catalyst and laser-assisted positioning.
Publisher
SAGE Publications,Sage Publications Ltd
Subject
This website uses cookies to ensure you get the best experience on our website.