MbrlCatalogueTitleDetail

Do you wish to reserve the book?
T1 reduction rate with Gd-EOB-DTPA determines liver function on both 1.5 T and 3 T MRI
T1 reduction rate with Gd-EOB-DTPA determines liver function on both 1.5 T and 3 T MRI
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
T1 reduction rate with Gd-EOB-DTPA determines liver function on both 1.5 T and 3 T MRI
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
T1 reduction rate with Gd-EOB-DTPA determines liver function on both 1.5 T and 3 T MRI
T1 reduction rate with Gd-EOB-DTPA determines liver function on both 1.5 T and 3 T MRI

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
T1 reduction rate with Gd-EOB-DTPA determines liver function on both 1.5 T and 3 T MRI
T1 reduction rate with Gd-EOB-DTPA determines liver function on both 1.5 T and 3 T MRI
Journal Article

T1 reduction rate with Gd-EOB-DTPA determines liver function on both 1.5 T and 3 T MRI

2022
Request Book From Autostore and Choose the Collection Method
Overview
Magnetic resonance T1 mapping before and after Gd-EOB-DTPA administration allows quantification of the T1 reduction rate as a non-invasive surrogate marker of liver function. A major limitation of T1 relaxation time measurement is its dependency on MRI field strengths. Since T1 reduction rate is calculated as the relative shortening of T1 relaxation time before and after contrast administration, we hypothesized that the T1 reduction rate is comparable between 1.5 and 3 T. We thus compared liver T1 relaxation times between 1.5 and 3 T in a total of 243 consecutive patients (124, 1.5 T and 119, 3 T) between 09/2018 and 07/2019. T1 reduction rates were compared between patients with no cirrhosis and patients with cirrhosis Child–Pugh A-C. There was no significant difference of T1 reduction rate between 1.5 and 3 T in any patient group (p-value 0.126–0.861). On both 1.5 T and 3 T, T1 reduction rate allowed to differentiate between patients with no cirrhosis and patients with liver cirrhosis Child A-C (p < 0.001). T1 reduction rate showed a good performance to predict liver cirrhosis Child A (AUC = 0.83, p < 0.001), Child B (AUC = 0.83, p < 0.001) and Child C (AUC = 0.92, p < 0.001). In conclusion, T1 reduction rate allows to determine liver function on Gd-EOB-DTPA MRI with comparable values on 1.5 T and 3 T.