MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Evaluation of internal exposure of nuclear medicine staff working with radioiodine in Poland
Evaluation of internal exposure of nuclear medicine staff working with radioiodine in Poland
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Evaluation of internal exposure of nuclear medicine staff working with radioiodine in Poland
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Evaluation of internal exposure of nuclear medicine staff working with radioiodine in Poland
Evaluation of internal exposure of nuclear medicine staff working with radioiodine in Poland

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Evaluation of internal exposure of nuclear medicine staff working with radioiodine in Poland
Evaluation of internal exposure of nuclear medicine staff working with radioiodine in Poland
Journal Article

Evaluation of internal exposure of nuclear medicine staff working with radioiodine in Poland

2023
Request Book From Autostore and Choose the Collection Method
Overview
The iodine-131 (I-131) content in the thyroid of staff members working with this radionuclides has been measured with about 500 employees in about 25 hospital's departments of nuclear medicine performing therapy and diagnosis of thyroid disease in Poland. The measurements were performed with portable detection unit for measurements of radioiodine. This is consist with scintillation detector sodium iodine activated by thallium (NaI(Tl)) - battery-powered and portable tube base Multichannel Analyzer Canberra UniSPEC. Based on direct measurements of the iodine content, the effective dose equivalent for workers due to inhalation of I-131 was estimated. All individuals actively working with iodine show measurable amounts of this isotopes in their thyroids. The average measured activity in the thyroid of the nuclear medicine staff was found to be equal at average 550 Bq within the range 70 Bq-2.5 kBq. There is no apparent correlation between the measured I-131 levels and risk categories. Nevertheless the technical and nuclear medicine staff show higher I-131 thyroid level comparing to hospital services staff. Calculated maximum committed effective dose for particular exposed person is <10% of 20 mSv/year. Int J Occup Med Environ Health. 2023;36(5):587-95.

MBRLCatalogueRelatedBooks