Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Endovascular Electroencephalogram Records Simultaneous Subdural Electrode-Detectable, Scalp Electrode-Undetectable Interictal Epileptiform Discharges
by
Fujimoto, Ayataka
, Masuda, Yosuke
, Hosoo, Hisayuki
, Marushima, Aiki
, Ishikawa, Eiichi
, Matsumaru, Yuji
, Araki, Kota
in
Anesthesia
/ Binding sites
/ Cardiovascular system
/ Communication
/ EEG
/ Electrodes
/ Electroencephalography
/ endovascular electroencephalogram
/ Epilepsy
/ Firing pattern
/ focal onset epilepsy
/ General anesthesia
/ interictal epileptiform discharge
/ Intubation
/ Laboratory animals
/ Latency
/ localized epileptogenicity
/ Magnetic resonance imaging
/ microcatheter
/ Sinuses
/ Titanium alloys
2022
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Endovascular Electroencephalogram Records Simultaneous Subdural Electrode-Detectable, Scalp Electrode-Undetectable Interictal Epileptiform Discharges
by
Fujimoto, Ayataka
, Masuda, Yosuke
, Hosoo, Hisayuki
, Marushima, Aiki
, Ishikawa, Eiichi
, Matsumaru, Yuji
, Araki, Kota
in
Anesthesia
/ Binding sites
/ Cardiovascular system
/ Communication
/ EEG
/ Electrodes
/ Electroencephalography
/ endovascular electroencephalogram
/ Epilepsy
/ Firing pattern
/ focal onset epilepsy
/ General anesthesia
/ interictal epileptiform discharge
/ Intubation
/ Laboratory animals
/ Latency
/ localized epileptogenicity
/ Magnetic resonance imaging
/ microcatheter
/ Sinuses
/ Titanium alloys
2022
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Endovascular Electroencephalogram Records Simultaneous Subdural Electrode-Detectable, Scalp Electrode-Undetectable Interictal Epileptiform Discharges
by
Fujimoto, Ayataka
, Masuda, Yosuke
, Hosoo, Hisayuki
, Marushima, Aiki
, Ishikawa, Eiichi
, Matsumaru, Yuji
, Araki, Kota
in
Anesthesia
/ Binding sites
/ Cardiovascular system
/ Communication
/ EEG
/ Electrodes
/ Electroencephalography
/ endovascular electroencephalogram
/ Epilepsy
/ Firing pattern
/ focal onset epilepsy
/ General anesthesia
/ interictal epileptiform discharge
/ Intubation
/ Laboratory animals
/ Latency
/ localized epileptogenicity
/ Magnetic resonance imaging
/ microcatheter
/ Sinuses
/ Titanium alloys
2022
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Endovascular Electroencephalogram Records Simultaneous Subdural Electrode-Detectable, Scalp Electrode-Undetectable Interictal Epileptiform Discharges
Journal Article
Endovascular Electroencephalogram Records Simultaneous Subdural Electrode-Detectable, Scalp Electrode-Undetectable Interictal Epileptiform Discharges
2022
Request Book From Autostore
and Choose the Collection Method
Overview
Introduction: We hypothesized that an endovascular electroencephalogram (eEEG) can detect subdural electrode (SDE)-detectable, scalp EEG-undetectable epileptiform discharges. The purpose of this study is, therefore, to measure SDE-detectable, scalp EEG-undetectable epileptiform discharges by an eEEG on a pig. Methods: A pig under general anesthesia was utilized to measure an artificially generated epileptic field by an eEEG that was able to be detected by an SDE, but not a scalp EEG as a primary outcome. We also compared the phase lag of each epileptiform discharge that was detected by the eEEG and SDE as a secondary outcome. Results: The eEEG electrode detected 113 (97%) epileptiform discharges (97% sensitivity). Epileptiform discharges that were localized within the three contacts (contacts two, three and four), but not spread to other parts, were detected by the eEEG with a 92% sensitivity. The latency between peaks of the eEEG and right SDE earliest epileptiform discharge ranged from 0 to 48 ms (mean, 13.3 ms; median, 11 ms; standard deviation, 9.0 ms). Conclusion: In a pig, an eEEG could detect epileptiform discharges that an SDE could detect, but that a scalp EEG could not.
Publisher
MDPI AG,MDPI
Subject
This website uses cookies to ensure you get the best experience on our website.