MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Accuracy of Doppler blood pressure measurement in HeartMate 3 ventricular assist device patients
Accuracy of Doppler blood pressure measurement in HeartMate 3 ventricular assist device patients
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Accuracy of Doppler blood pressure measurement in HeartMate 3 ventricular assist device patients
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Accuracy of Doppler blood pressure measurement in HeartMate 3 ventricular assist device patients
Accuracy of Doppler blood pressure measurement in HeartMate 3 ventricular assist device patients

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Accuracy of Doppler blood pressure measurement in HeartMate 3 ventricular assist device patients
Accuracy of Doppler blood pressure measurement in HeartMate 3 ventricular assist device patients
Journal Article

Accuracy of Doppler blood pressure measurement in HeartMate 3 ventricular assist device patients

2020
Request Book From Autostore and Choose the Collection Method
Overview
Aims Optimal blood pressure (BP) control is imperative to reduce complications, especially strokes, in continuous flow ventricular assist device (VAD) patients. Doppler BP has been shown to be an accurate and reliable non‐invasive BP measurement method in HeartMate II and HVAD patients. We examined whether Doppler BP is also accurate in patients with the HeartMate 3 VAD. Methods and results In a prospective, longitudinal cohort of HeartMate 3 patients, arterial line BP and simultaneously measured Doppler opening pressure were obtained. Correlation and agreement between Doppler opening pressure and arterial line mean arterial pressure (MAP) versus systolic blood pressure (SBP) were analysed, as well as the effect of pulse pressure on the accuracy of Doppler opening pressure. A total of 589 pairs of simultaneous Doppler opening pressure and arterial line pressure readings were obtained in 43 patients. Doppler opening pressure had good correlation with intra‐arterial MAP (r = 0.754) and more closely approximated MAP than SBP (mean error 2.0 vs. −8.6 mmHg). Pulse pressure did not have a clinically significant impact on the accuracy of the Doppler BP method. These results in HeartMate 3 patients are very similar to previous results in HeartMate II and HVAD patients. Conclusions Doppler BP method should be the default non‐invasive BP measurement method in continuous flow VAD patients including patients implanted with the HeartMate 3.