Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Development of a Real-Time Pixel Array-Type Detector for Ultrahigh Dose-Rate Beams
by
Choi, Sang Hyoun
, Kim, Geun-Beom
, Yang, Tae Keun
, Kim, Kum Bae
, Jeong, Jong Hwi
, Kim, Jeong Hwan
, Park, Seong Hee
, Jang, Young Jae
, Jang, Hong Suk
in
2D pixel array detector
/ collection efficiency
/ Data processing
/ Detectors
/ Efficiency
/ Electrodes
/ FLASH
/ Monitoring systems
/ Monte Carlo method
/ Monte Carlo simulation
/ Radiation
/ Radiotherapy
/ Real time
/ real-time monitoring
/ Sensors
/ Software
/ ultrahigh dose-rate beam
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Development of a Real-Time Pixel Array-Type Detector for Ultrahigh Dose-Rate Beams
by
Choi, Sang Hyoun
, Kim, Geun-Beom
, Yang, Tae Keun
, Kim, Kum Bae
, Jeong, Jong Hwi
, Kim, Jeong Hwan
, Park, Seong Hee
, Jang, Young Jae
, Jang, Hong Suk
in
2D pixel array detector
/ collection efficiency
/ Data processing
/ Detectors
/ Efficiency
/ Electrodes
/ FLASH
/ Monitoring systems
/ Monte Carlo method
/ Monte Carlo simulation
/ Radiation
/ Radiotherapy
/ Real time
/ real-time monitoring
/ Sensors
/ Software
/ ultrahigh dose-rate beam
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Development of a Real-Time Pixel Array-Type Detector for Ultrahigh Dose-Rate Beams
by
Choi, Sang Hyoun
, Kim, Geun-Beom
, Yang, Tae Keun
, Kim, Kum Bae
, Jeong, Jong Hwi
, Kim, Jeong Hwan
, Park, Seong Hee
, Jang, Young Jae
, Jang, Hong Suk
in
2D pixel array detector
/ collection efficiency
/ Data processing
/ Detectors
/ Efficiency
/ Electrodes
/ FLASH
/ Monitoring systems
/ Monte Carlo method
/ Monte Carlo simulation
/ Radiation
/ Radiotherapy
/ Real time
/ real-time monitoring
/ Sensors
/ Software
/ ultrahigh dose-rate beam
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Development of a Real-Time Pixel Array-Type Detector for Ultrahigh Dose-Rate Beams
Journal Article
Development of a Real-Time Pixel Array-Type Detector for Ultrahigh Dose-Rate Beams
2023
Request Book From Autostore
and Choose the Collection Method
Overview
Although research into ultrahigh dose-rate (UHDR) radiation therapy is ongoing, there is a significant lack of experimental measurements for two-dimensional (2D) dose-rate distributions. Additionally, conventional pixel-type detectors result in significant beam loss. In this study, we developed a pixel array-type detector with adjustable gaps and a data acquisition system to evaluate its effectiveness in measuring UHDR proton beams in real time. We measured a UHDR beam at the Korea Institute of Radiological and Medical Sciences using an MC-50 cyclotron, which produced a 45-MeV energy beam with a current range of 10–70 nA, to confirm the UHDR beam conditions. To minimize beam loss during measurement, we adjusted the gap and high voltage on the detector and determined the collection efficiency of the developed detector through Monte Carlo simulation and experimental measurements of the 2D dose-rate distribution. We also verified the accuracy of the real-time position measurement using the developed detector with a 226.29-MeV PBS beam at the National Cancer Center of the Republic of Korea. Our results indicate that, for a current of 70 nA with an energy beam of 45 MeV generated using the MC-50 cyclotron, the dose rate exceeded 300 Gy/s at the center of the beam, indicating UHDR conditions. Simulation and experimental measurements show that fixing the gap at 2 mm and the high voltage at 1000 V resulted in a less than 1% loss of collection efficiency when measuring UHDR beams. Furthermore, we achieved real-time measurements of the beam position with an accuracy of within 2% at five reference points. In conclusion, our study developed a beam monitoring system that can measure UHDR proton beams and confirmed the accuracy of the beam position and profile through real-time data transmission.
Publisher
MDPI AG,MDPI
This website uses cookies to ensure you get the best experience on our website.