MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Feasibility of using respiration‐averaged MR images for attenuation correction of cardiac PET/MR imaging
Feasibility of using respiration‐averaged MR images for attenuation correction of cardiac PET/MR imaging
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Feasibility of using respiration‐averaged MR images for attenuation correction of cardiac PET/MR imaging
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Feasibility of using respiration‐averaged MR images for attenuation correction of cardiac PET/MR imaging
Feasibility of using respiration‐averaged MR images for attenuation correction of cardiac PET/MR imaging

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Feasibility of using respiration‐averaged MR images for attenuation correction of cardiac PET/MR imaging
Feasibility of using respiration‐averaged MR images for attenuation correction of cardiac PET/MR imaging
Journal Article

Feasibility of using respiration‐averaged MR images for attenuation correction of cardiac PET/MR imaging

2015
Request Book From Autostore and Choose the Collection Method
Overview
Cardiac imaging is a promising application for combined PET/MR imaging. However, current MR imaging protocols for whole‐body attenuation correction can produce spatial mismatch between PET and MR‐derived attenuation data owing to a disparity between the two modalities' imaging speeds. We assessed the feasibility of using a respiration‐averaged MR (AMR) method for attenuation correction of cardiac PET data in PET/MR images. First, to demonstrate the feasibility of motion imaging with MR, we used a 3T MR system and a two‐dimensional fast spoiled gradient‐recalled echo (SPGR) sequence to obtain AMR images of a moving phantom. Then, we used the same sequence to obtain AMR images of a patient's thorax under free‐breathing conditions. MR images were converted into PET attenuation maps using a three‐class tissue segmentation method with two sets of predetermined CT numbers, one calculated from the patient‐specific (PS) CT images and the other from a reference group (RG) containing 54 patient CT datasets. The MR‐derived attenuation images were then used for attenuation correction of the cardiac PET data, which were compared to the PET data corrected with average CT (ACT) images. In the myocardium, the voxel‐by‐voxel differences and the differences in mean slice activity between the AMR‐corrected PET data and the ACT‐corrected PET data were found to be small (less than 7%). The use of AMR‐derived attenuation images in place of ACT images for attenuation correction did not affect the summed stress score. These results demonstrate the feasibility of using the proposed SPGR‐based MR imaging protocol to obtain patient AMR images and using those images for cardiac PET attenuation correction. Additional studies with more clinical data are warranted to further evaluate the method. PACS number: 87.57.uk