Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Validity of architectural properties of the hamstring muscles: Correlation of ultrasound findings with cadaveric dissection
by
Kellis, Eleftherios
, Galanis, Nikiforos
, Kapetanos, George
, Natsis, Konstantinos
in
Aged
/ Architecture
/ Biceps femoris
/ Cadaver
/ Dissection
/ Humans
/ Image Interpretation, Computer-Assisted - methods
/ Knee flexors
/ Leg - physiology
/ Male
/ Morphology
/ Muscle mechanics
/ Muscle, Skeletal - anatomy & histology
/ Muscle, Skeletal - diagnostic imaging
/ Personal relationships
/ Physical Medicine and Rehabilitation
/ Reproducibility of Results
/ Semitendinosus
/ Sensitivity and Specificity
/ Statistics as Topic
/ Tendons - anatomy & histology
/ Tendons - diagnostic imaging
/ Ultrasonography
/ Validity
2009
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Validity of architectural properties of the hamstring muscles: Correlation of ultrasound findings with cadaveric dissection
by
Kellis, Eleftherios
, Galanis, Nikiforos
, Kapetanos, George
, Natsis, Konstantinos
in
Aged
/ Architecture
/ Biceps femoris
/ Cadaver
/ Dissection
/ Humans
/ Image Interpretation, Computer-Assisted - methods
/ Knee flexors
/ Leg - physiology
/ Male
/ Morphology
/ Muscle mechanics
/ Muscle, Skeletal - anatomy & histology
/ Muscle, Skeletal - diagnostic imaging
/ Personal relationships
/ Physical Medicine and Rehabilitation
/ Reproducibility of Results
/ Semitendinosus
/ Sensitivity and Specificity
/ Statistics as Topic
/ Tendons - anatomy & histology
/ Tendons - diagnostic imaging
/ Ultrasonography
/ Validity
2009
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Validity of architectural properties of the hamstring muscles: Correlation of ultrasound findings with cadaveric dissection
by
Kellis, Eleftherios
, Galanis, Nikiforos
, Kapetanos, George
, Natsis, Konstantinos
in
Aged
/ Architecture
/ Biceps femoris
/ Cadaver
/ Dissection
/ Humans
/ Image Interpretation, Computer-Assisted - methods
/ Knee flexors
/ Leg - physiology
/ Male
/ Morphology
/ Muscle mechanics
/ Muscle, Skeletal - anatomy & histology
/ Muscle, Skeletal - diagnostic imaging
/ Personal relationships
/ Physical Medicine and Rehabilitation
/ Reproducibility of Results
/ Semitendinosus
/ Sensitivity and Specificity
/ Statistics as Topic
/ Tendons - anatomy & histology
/ Tendons - diagnostic imaging
/ Ultrasonography
/ Validity
2009
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Validity of architectural properties of the hamstring muscles: Correlation of ultrasound findings with cadaveric dissection
Journal Article
Validity of architectural properties of the hamstring muscles: Correlation of ultrasound findings with cadaveric dissection
2009
Request Book From Autostore
and Choose the Collection Method
Overview
The purpose of this study was to compare the architectural parameters of the long head of biceps femoris (BFlh) and semitendinosus (ST) muscles by comparing measurements from ultrasound (US) with those obtained from direct dissection. The BFlh and ST architectures were examined bilaterally in 6 legs from 3 male cadavers. The fascicle length, pennation angle, muscle thickness and muscle and tendon length were obtained from direct measurement and US scans along each muscle. Intraclass correlation coefficients between the two methods ranged from 0.905 to 0.913 for the BFlh variables and from 0.774 to 0.974 for the ST parameters. Compared with the direct measurements, the US method showed a mean typical error of 0.09–0.14
cm for muscle thickness, 1.01–1.31° for the pennation angle, 0.92–1.71
cm for fascicle length and muscle–tendon length measurements. The US method is a valid alternative tool for assessing basic architectural parameters of ST and BFlh components of the hamstring muscles.
Publisher
Elsevier Ltd,Elsevier Limited
This website uses cookies to ensure you get the best experience on our website.