MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Clinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery
Clinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Clinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Clinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery
Clinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Clinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery
Clinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery
Journal Article

Clinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery

2016
Request Book From Autostore and Choose the Collection Method
Overview
Background Temporary pacemaker wires are placed in the majority of patients after cardiac surgery. There is no information on mechanical factors related to wire removal. Methods Clinical information related to temporary wire use and removal was prospectively collected from a large cardiac surgical unit over one year. Measurements of maximal tension that nurses and doctors would apply to remove temporary wires was determined using a hand-held portable scale. In a prospective trial, patients ( n  = 41) had their wires extracted in series to the portable scale to determine the maximal tension required for safe removal. Results Ventricular wires were placed in 86.5 % of patients during the observed year. Pacing facilitated weaning from CPB in over 15 % of patients and pacer dependence was seen in 2.1 %. No patients suffered major complications after wire removal. There was no difference in the tension that physicians or nurses would apply to comfortably extract temporary wires. In the prospective trial, there was no difference in the tension required for removal of atrial or ventricular wires (atrial 18.3 ± 17.9 oz versus 14.5 ± 14.2 oz, p  = 0.430). There were no patient factors that correlated with the degree of resistance and there was no significant difference between the tension required to remove wires with (21.0 ± 22.5 oz) or without (14.1 ± 5.1 oz) an atrial button. Conclusions Temporary epicardial wire removal is innocuous and was not associated with any complications. In some patients tension required for safe removal exceeded 20 ounces. Strategies to standardize wire removal may prevent complications and may minimize unnecessary wire retention.