Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Use of thin-layer chromatography to detect counterfeit sulfadoxine/pyrimethamine tablets with the wrong active ingredient in Malawi
by
Kigera, Stephen
, Heide, Lutz
, Khuluza, Felix
, Jähnke, Richard W. O.
in
Acetaminophen - analysis
/ Antimalarials
/ Antimalarials - analysis
/ Appropriate technology
/ Biomedical and Life Sciences
/ Biomedicine
/ Care and treatment
/ Chromatography, Thin Layer - instrumentation
/ Complications and side effects
/ Counterfeit Drugs - analysis
/ Drug Combinations
/ Entomology
/ Feasibility Studies
/ Health aspects
/ Health risks
/ Infectious Diseases
/ Liquid chromatography
/ Low income areas
/ Malaria
/ Malawi
/ Methodology
/ Microbiology
/ Parasitology
/ Public Health
/ Pyrimethamine - analysis
/ Quality Control
/ Solvents
/ Sulfadoxine - analysis
/ Tablets - analysis
/ Technology, Pharmaceutical - methods
/ Thin layer chromatography
/ Trimethoprim, Sulfamethoxazole Drug Combination - analysis
/ Tropical Medicine
2016
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Use of thin-layer chromatography to detect counterfeit sulfadoxine/pyrimethamine tablets with the wrong active ingredient in Malawi
by
Kigera, Stephen
, Heide, Lutz
, Khuluza, Felix
, Jähnke, Richard W. O.
in
Acetaminophen - analysis
/ Antimalarials
/ Antimalarials - analysis
/ Appropriate technology
/ Biomedical and Life Sciences
/ Biomedicine
/ Care and treatment
/ Chromatography, Thin Layer - instrumentation
/ Complications and side effects
/ Counterfeit Drugs - analysis
/ Drug Combinations
/ Entomology
/ Feasibility Studies
/ Health aspects
/ Health risks
/ Infectious Diseases
/ Liquid chromatography
/ Low income areas
/ Malaria
/ Malawi
/ Methodology
/ Microbiology
/ Parasitology
/ Public Health
/ Pyrimethamine - analysis
/ Quality Control
/ Solvents
/ Sulfadoxine - analysis
/ Tablets - analysis
/ Technology, Pharmaceutical - methods
/ Thin layer chromatography
/ Trimethoprim, Sulfamethoxazole Drug Combination - analysis
/ Tropical Medicine
2016
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Use of thin-layer chromatography to detect counterfeit sulfadoxine/pyrimethamine tablets with the wrong active ingredient in Malawi
by
Kigera, Stephen
, Heide, Lutz
, Khuluza, Felix
, Jähnke, Richard W. O.
in
Acetaminophen - analysis
/ Antimalarials
/ Antimalarials - analysis
/ Appropriate technology
/ Biomedical and Life Sciences
/ Biomedicine
/ Care and treatment
/ Chromatography, Thin Layer - instrumentation
/ Complications and side effects
/ Counterfeit Drugs - analysis
/ Drug Combinations
/ Entomology
/ Feasibility Studies
/ Health aspects
/ Health risks
/ Infectious Diseases
/ Liquid chromatography
/ Low income areas
/ Malaria
/ Malawi
/ Methodology
/ Microbiology
/ Parasitology
/ Public Health
/ Pyrimethamine - analysis
/ Quality Control
/ Solvents
/ Sulfadoxine - analysis
/ Tablets - analysis
/ Technology, Pharmaceutical - methods
/ Thin layer chromatography
/ Trimethoprim, Sulfamethoxazole Drug Combination - analysis
/ Tropical Medicine
2016
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Use of thin-layer chromatography to detect counterfeit sulfadoxine/pyrimethamine tablets with the wrong active ingredient in Malawi
Journal Article
Use of thin-layer chromatography to detect counterfeit sulfadoxine/pyrimethamine tablets with the wrong active ingredient in Malawi
2016
Request Book From Autostore
and Choose the Collection Method
Overview
Background
Substandard and falsified anti-malarial medicines pose a serious threat to public health, especially in low-income countries. Appropriate technologies for drug quality analysis in resource-limited settings are important for the surveillance of the formal and informal drug market. The feasibility of thin-layer chromatography (TLC) with different solvent systems was tested using the GPHF Minilab in a study of the quality of sulfadoxine/pyrimethamine tablets in Malawi.
Methods
Twenty eight samples of sulfadoxine/pyrimethamine tablets were collected from randomly selected health facilities of four districts of southern Malawi. A mystery shopper approach was used when collecting samples from illegal street vendors, and an overt approach for the other facilities. Samples were subjected to visual inspection, disintegration testing and TLC analysis. 10 samples were further investigated according to the methods of the US Pharmacopeia using high performance liquid chromatography (HPLC).
Results
One sample was found to be falsified, containing a mixture of paracetamol tablets and co-trimoxazole tablets. These had been repackaged into paper strip packs labelled as a brand of sulfadoxine/pyrimethamine. TLC with different solvent systems readily proved that these tablets did not comply with their declaration, and provided strong evidence for the active pharmaceutical ingredients which were actually contained. Full pharmacopeial analysis by HPLC confirmed the results suggested by TLC for this sample, and showed two further samples to be of substandard quality.
Conclusions
Due to the absence of the declared anti-malarial ingredients and due to the presence of other pharmaceutical ingredients, the identified falsified medicine represents a serious health risk for the population. Thin-layer chromatography (TLC) using different solvent systems proved to be a powerful method for the identification of this type of counterfeiting, presenting a simple and affordable technology for use in resource-limited settings.
Publisher
BioMed Central,BioMed Central Ltd,Springer Nature B.V
This website uses cookies to ensure you get the best experience on our website.