Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint
by
Jacobs, Christopher R.
, Rashid, Mark M.
, Haut Donahue, Tammy L.
, Hull, M.L.
in
Adult
/ Arthroplasty, Replacement, Knee - methods
/ Cadaver
/ Computer Simulation
/ Contact
/ Elasticity
/ Femur - anatomy & histology
/ Femur - physiology
/ Finite Element Analysis
/ Finite element method
/ Humans
/ In Vitro Techniques
/ Knee
/ Knee Joint - anatomy & histology
/ Knee Joint - physiology
/ Male
/ Material properties
/ Menisci, Tibial - anatomy & histology
/ Menisci, Tibial - physiology
/ Meniscus
/ Models, Biological
/ Pressure
/ Quality Control
/ Reproducibility of Results
/ Sensitivity and Specificity
/ Stress, Mechanical
/ Tibia - anatomy & histology
/ Tibia - physiology
/ Weight-Bearing - physiology
2003
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint
by
Jacobs, Christopher R.
, Rashid, Mark M.
, Haut Donahue, Tammy L.
, Hull, M.L.
in
Adult
/ Arthroplasty, Replacement, Knee - methods
/ Cadaver
/ Computer Simulation
/ Contact
/ Elasticity
/ Femur - anatomy & histology
/ Femur - physiology
/ Finite Element Analysis
/ Finite element method
/ Humans
/ In Vitro Techniques
/ Knee
/ Knee Joint - anatomy & histology
/ Knee Joint - physiology
/ Male
/ Material properties
/ Menisci, Tibial - anatomy & histology
/ Menisci, Tibial - physiology
/ Meniscus
/ Models, Biological
/ Pressure
/ Quality Control
/ Reproducibility of Results
/ Sensitivity and Specificity
/ Stress, Mechanical
/ Tibia - anatomy & histology
/ Tibia - physiology
/ Weight-Bearing - physiology
2003
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint
by
Jacobs, Christopher R.
, Rashid, Mark M.
, Haut Donahue, Tammy L.
, Hull, M.L.
in
Adult
/ Arthroplasty, Replacement, Knee - methods
/ Cadaver
/ Computer Simulation
/ Contact
/ Elasticity
/ Femur - anatomy & histology
/ Femur - physiology
/ Finite Element Analysis
/ Finite element method
/ Humans
/ In Vitro Techniques
/ Knee
/ Knee Joint - anatomy & histology
/ Knee Joint - physiology
/ Male
/ Material properties
/ Menisci, Tibial - anatomy & histology
/ Menisci, Tibial - physiology
/ Meniscus
/ Models, Biological
/ Pressure
/ Quality Control
/ Reproducibility of Results
/ Sensitivity and Specificity
/ Stress, Mechanical
/ Tibia - anatomy & histology
/ Tibia - physiology
/ Weight-Bearing - physiology
2003
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint
Journal Article
How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint
2003
Request Book From Autostore
and Choose the Collection Method
Overview
In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements are subjects of current interest and investigation. The objectives of the current study were to (1) determine whether a transversely isotropic, linearly elastic, homogeneous material model of the meniscal tissue is necessary to achieve a normal contact pressure distribution on the tibial plateau, (2) determine which material and boundary condition (attachments) parameters affect the contact pressure distribution most strongly, and (3) set tolerances on these parameters to restore the contact pressure distribution to within a specified error. To satisfy these objectives, a finite element model of the tibio-femoral joint of a human cadaveric knee (including both menisci) was used to study the contact pressure distribution on the tibial plateau. To validate the model, the contact pressure distribution on the tibial plateau was measured experimentally in the same knee used to create the model. Within physiologically reasonable bounds on five material parameters and four attachment parameters associated with a meniscal replacement, an optimization was performed under 1200
N of compressive load on the set of nine parameters to minimize the difference between the experimental and model results. The error between the experimental and model contact variables was minimized to 5.4%. The contact pressure distribution of the tibial plateau was sensitive to the circumferential modulus, axial/radial modulus, and horn stiffness, but relatively insensitive to the remaining six parameters. Consequently, both the circumferential and axial/radial moduli are important determinants of the contact pressure distribution, and hence should be matched in the design and/or selection of meniscal replacements. In addition, during surgical implantation of a meniscal replacement, the horns should be attached with high stiffness bone plugs, and the attachments of the transverse ligament and deep medial collateral ligament should be restored to minimize changes in the contact pressure distribution, and thereby possibly prevent the degradation of articular cartilage.
Publisher
Elsevier Ltd,Elsevier Limited
This website uses cookies to ensure you get the best experience on our website.