Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Development of a headgear-based eye protection device for physicians performing fluoroscopy-guided bronchoscopy
by
Suzuki, Masatoshi
, Chida, Koichi
, Sota, Masahiro
, Abe, Mitsuya
, Kaga, Yuji
, Haga, Yoshihiro
, Fujisawa, Masaki
, Inaba, Yohei
, Kato, Toshiki
, Takahira, Saki
in
Bronchoscopy
/ Cataract
/ Cataracts
/ Diagnosis
/ Equipment Design
/ Eye protection
/ Eye Protective Devices
/ Fluoroscopy
/ Forecasts and trends
/ Fundamental Radiation Science
/ Headgear
/ Humans
/ Lenses
/ Lung cancer
/ Lung diseases
/ Medical colleges
/ Occupational Exposure - prevention & control
/ Phantoms, Imaging
/ Physicians
/ Radiation
/ Radiation Dosage
/ Radiation effects
/ Radiation injuries
/ Radiation protection
/ Radiation Protection - instrumentation
/ Radiation, Background
2025
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Development of a headgear-based eye protection device for physicians performing fluoroscopy-guided bronchoscopy
by
Suzuki, Masatoshi
, Chida, Koichi
, Sota, Masahiro
, Abe, Mitsuya
, Kaga, Yuji
, Haga, Yoshihiro
, Fujisawa, Masaki
, Inaba, Yohei
, Kato, Toshiki
, Takahira, Saki
in
Bronchoscopy
/ Cataract
/ Cataracts
/ Diagnosis
/ Equipment Design
/ Eye protection
/ Eye Protective Devices
/ Fluoroscopy
/ Forecasts and trends
/ Fundamental Radiation Science
/ Headgear
/ Humans
/ Lenses
/ Lung cancer
/ Lung diseases
/ Medical colleges
/ Occupational Exposure - prevention & control
/ Phantoms, Imaging
/ Physicians
/ Radiation
/ Radiation Dosage
/ Radiation effects
/ Radiation injuries
/ Radiation protection
/ Radiation Protection - instrumentation
/ Radiation, Background
2025
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Development of a headgear-based eye protection device for physicians performing fluoroscopy-guided bronchoscopy
by
Suzuki, Masatoshi
, Chida, Koichi
, Sota, Masahiro
, Abe, Mitsuya
, Kaga, Yuji
, Haga, Yoshihiro
, Fujisawa, Masaki
, Inaba, Yohei
, Kato, Toshiki
, Takahira, Saki
in
Bronchoscopy
/ Cataract
/ Cataracts
/ Diagnosis
/ Equipment Design
/ Eye protection
/ Eye Protective Devices
/ Fluoroscopy
/ Forecasts and trends
/ Fundamental Radiation Science
/ Headgear
/ Humans
/ Lenses
/ Lung cancer
/ Lung diseases
/ Medical colleges
/ Occupational Exposure - prevention & control
/ Phantoms, Imaging
/ Physicians
/ Radiation
/ Radiation Dosage
/ Radiation effects
/ Radiation injuries
/ Radiation protection
/ Radiation Protection - instrumentation
/ Radiation, Background
2025
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Development of a headgear-based eye protection device for physicians performing fluoroscopy-guided bronchoscopy
Journal Article
Development of a headgear-based eye protection device for physicians performing fluoroscopy-guided bronchoscopy
2025
Request Book From Autostore
and Choose the Collection Method
Overview
Fluoroscopy-guided bronchoscopy is an essential tool for diagnosing and treating lung diseases, particularly lung cancer. However, prolonged fluoroscopic exposure raises concerns regarding radiation-induced lens injuries in physicians, such as radiation cataracts. In response to the International Commission on Radiological Protection lowering the occupational lens dose limit to an average of 20 mSv/year over 5 years, there is an increasing need for effective lens protection during such procedures. This study has aimed to develop a novel lens protection device specifically designed for bronchoscopy physicians and evaluate its protective performance through a phantom study. The device consisted of a 0.175 mm lead (Pb) sheet positioned on the left side of the physician’s head, secured with headgear to improve stability and comfort during prolonged use. A phantom study was conducted using a trunk phantom to simulate a patient and a head phantom to simulate a physician. The scattered radiation doses were measured at 15 locations on the phantom head using a radiophotoluminescence glass dosimeter, both with and without a protective device. The device demonstrated a protective effect of more than 80% for the left eye across all tested angles, whereas the right eye showed protection ranging from approximately 40% to 75% depending on the angle. This novel lens protection device has the potential to significantly reduce scattered radiation to the left eye while minimizing vision obstruction and discomfort. This offers a practical solution for radiation protection during bronchoscopy and may be applicable to other interventional procedures requiring fluoroscopic guidance.
Publisher
Oxford University Press
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.