Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Multidetector-Row Computed Tomography in Suspected Pulmonary Embolism
by
Davido, Alain
, Sanchez, Olivier
, Roy, Pierre-Marie
, Meyer, Guy
, Furber, Alain
, Revel, Marie-Pierre
, Le Gal, Grégoire
, Howarth, Nigel
, Gourdier, Anne-Laurence
, Perrier, Arnaud
, Bounameaux, Henri
in
Aged
/ Aged, 80 and over
/ Anticoagulants
/ Anticoagulants - therapeutic use
/ Biological and medical sciences
/ Blood clots
/ Female
/ Femoral Vein
/ Femoral Vein - diagnostic imaging
/ Fibrin Fibrinogen Degradation Products
/ Fibrin Fibrinogen Degradation Products - analysis
/ Follow-Up Studies
/ General aspects
/ Human health and pathology
/ Humans
/ Life Sciences
/ Male
/ Medical diagnosis
/ Medical imaging
/ Medical sciences
/ Middle Aged
/ Pneumology
/ Popliteal Vein
/ Popliteal Vein - diagnostic imaging
/ Predictive Value of Tests
/ Prospective Studies
/ Pulmonary arteries
/ Pulmonary Artery
/ Pulmonary Artery - diagnostic imaging
/ Pulmonary Embolism
/ Pulmonary Embolism - diagnosis
/ Pulmonary Embolism - diagnostic imaging
/ Pulmonary Embolism - etiology
/ Pulmonary hypertension. Acute cor pulmonale. Pulmonary embolism. Pulmonary vascular diseases
/ Thromboembolism
/ Thromboembolism - diagnosis
/ Tomography, X-Ray Computed
/ Tomography, X-Ray Computed - methods
/ Ultrasonography
/ Venous Thrombosis
/ Venous Thrombosis - complications
/ Venous Thrombosis - diagnostic imaging
2005
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Multidetector-Row Computed Tomography in Suspected Pulmonary Embolism
by
Davido, Alain
, Sanchez, Olivier
, Roy, Pierre-Marie
, Meyer, Guy
, Furber, Alain
, Revel, Marie-Pierre
, Le Gal, Grégoire
, Howarth, Nigel
, Gourdier, Anne-Laurence
, Perrier, Arnaud
, Bounameaux, Henri
in
Aged
/ Aged, 80 and over
/ Anticoagulants
/ Anticoagulants - therapeutic use
/ Biological and medical sciences
/ Blood clots
/ Female
/ Femoral Vein
/ Femoral Vein - diagnostic imaging
/ Fibrin Fibrinogen Degradation Products
/ Fibrin Fibrinogen Degradation Products - analysis
/ Follow-Up Studies
/ General aspects
/ Human health and pathology
/ Humans
/ Life Sciences
/ Male
/ Medical diagnosis
/ Medical imaging
/ Medical sciences
/ Middle Aged
/ Pneumology
/ Popliteal Vein
/ Popliteal Vein - diagnostic imaging
/ Predictive Value of Tests
/ Prospective Studies
/ Pulmonary arteries
/ Pulmonary Artery
/ Pulmonary Artery - diagnostic imaging
/ Pulmonary Embolism
/ Pulmonary Embolism - diagnosis
/ Pulmonary Embolism - diagnostic imaging
/ Pulmonary Embolism - etiology
/ Pulmonary hypertension. Acute cor pulmonale. Pulmonary embolism. Pulmonary vascular diseases
/ Thromboembolism
/ Thromboembolism - diagnosis
/ Tomography, X-Ray Computed
/ Tomography, X-Ray Computed - methods
/ Ultrasonography
/ Venous Thrombosis
/ Venous Thrombosis - complications
/ Venous Thrombosis - diagnostic imaging
2005
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Multidetector-Row Computed Tomography in Suspected Pulmonary Embolism
by
Davido, Alain
, Sanchez, Olivier
, Roy, Pierre-Marie
, Meyer, Guy
, Furber, Alain
, Revel, Marie-Pierre
, Le Gal, Grégoire
, Howarth, Nigel
, Gourdier, Anne-Laurence
, Perrier, Arnaud
, Bounameaux, Henri
in
Aged
/ Aged, 80 and over
/ Anticoagulants
/ Anticoagulants - therapeutic use
/ Biological and medical sciences
/ Blood clots
/ Female
/ Femoral Vein
/ Femoral Vein - diagnostic imaging
/ Fibrin Fibrinogen Degradation Products
/ Fibrin Fibrinogen Degradation Products - analysis
/ Follow-Up Studies
/ General aspects
/ Human health and pathology
/ Humans
/ Life Sciences
/ Male
/ Medical diagnosis
/ Medical imaging
/ Medical sciences
/ Middle Aged
/ Pneumology
/ Popliteal Vein
/ Popliteal Vein - diagnostic imaging
/ Predictive Value of Tests
/ Prospective Studies
/ Pulmonary arteries
/ Pulmonary Artery
/ Pulmonary Artery - diagnostic imaging
/ Pulmonary Embolism
/ Pulmonary Embolism - diagnosis
/ Pulmonary Embolism - diagnostic imaging
/ Pulmonary Embolism - etiology
/ Pulmonary hypertension. Acute cor pulmonale. Pulmonary embolism. Pulmonary vascular diseases
/ Thromboembolism
/ Thromboembolism - diagnosis
/ Tomography, X-Ray Computed
/ Tomography, X-Ray Computed - methods
/ Ultrasonography
/ Venous Thrombosis
/ Venous Thrombosis - complications
/ Venous Thrombosis - diagnostic imaging
2005
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Multidetector-Row Computed Tomography in Suspected Pulmonary Embolism
Journal Article
Multidetector-Row Computed Tomography in Suspected Pulmonary Embolism
2005
Request Book From Autostore
and Choose the Collection Method
Overview
The role of multidetector-row computed tomography (CT) in the diagnosis of pulmonary embolism remains to be determined. In this study, the combined use of multidetector-row CT and D-dimer assays allowed pulmonary embolism to be excluded without the need for lower-extremity ultrasonography.
The combined use of multidetector-row CT and D-dimer assays allowed pulmonary embolism to be excluded without the need for lower-extremity ultrasonography.
Computed tomography (CT) is increasingly being used as the main thoracic imaging technique in suspected pulmonary embolism.
1
–
4
First-generation single-detector–row helical CT scanners have a 90 percent specificity but only a 70 percent sensitivity for pulmonary embolism.
5
–
8
In series in which venous-compression ultrasonography of the lower limbs and single-detector–row helical CT were performed in all patients with clinically suspected pulmonary embolism,
7
,
9
the proportion of patients with deep venous thrombosis despite findings on CT that were negative for pulmonary embolism was 6 to 9 percent. The implication of this finding is that lower-limb ultrasonography must be combined with CT . . .
Publisher
Massachusetts Medical Society
Subject
/ Anticoagulants - therapeutic use
/ Biological and medical sciences
/ Female
/ Femoral Vein - diagnostic imaging
/ Fibrin Fibrinogen Degradation Products
/ Fibrin Fibrinogen Degradation Products - analysis
/ Humans
/ Male
/ Popliteal Vein - diagnostic imaging
/ Pulmonary Artery - diagnostic imaging
/ Pulmonary Embolism - diagnosis
/ Pulmonary Embolism - diagnostic imaging
/ Pulmonary Embolism - etiology
/ Pulmonary hypertension. Acute cor pulmonale. Pulmonary embolism. Pulmonary vascular diseases
/ Tomography, X-Ray Computed - methods
This website uses cookies to ensure you get the best experience on our website.