MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Accuracy of ZedView, the Software for Three-Dimensional Measurement and Preoperative Planning: A Basic Study
Accuracy of ZedView, the Software for Three-Dimensional Measurement and Preoperative Planning: A Basic Study
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Accuracy of ZedView, the Software for Three-Dimensional Measurement and Preoperative Planning: A Basic Study
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Accuracy of ZedView, the Software for Three-Dimensional Measurement and Preoperative Planning: A Basic Study
Accuracy of ZedView, the Software for Three-Dimensional Measurement and Preoperative Planning: A Basic Study

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Accuracy of ZedView, the Software for Three-Dimensional Measurement and Preoperative Planning: A Basic Study
Accuracy of ZedView, the Software for Three-Dimensional Measurement and Preoperative Planning: A Basic Study
Journal Article

Accuracy of ZedView, the Software for Three-Dimensional Measurement and Preoperative Planning: A Basic Study

2023
Request Book From Autostore and Choose the Collection Method
Overview
Background and Objectives: In the field of orthopedic surgery, novel techniques of three-dimensional shape modeling using two-dimensional tomographic images are used for bone-shape measurements, preoperative planning in joint-replacement surgery, and postoperative evaluation. ZedView® (three-dimensional measurement instrument and preoperative-planning software) had previously been developed. Our group is also using ZedView® for preoperative planning and postoperative evaluation for more accurate implant placement and osteotomy. This study aimed to evaluate the measurement error in this software in comparison to a three-dimensional measuring instrument (3DMI) using human bones. Materials and Methods: The study was conducted using three bones from cadavers: the pelvic bone, femur, and tibia. Three markers were attached to each bone. Study 1: The bones with markers were fixed on the 3DMI. For each bone, the coordinates of the center point of the markers were measured, and the distances and angles between these three points were calculated and defined as “true values.” Study 2: The posterior surface of the femur was placed face down on the 3DMI, and the distances from the table to the center of each marker were measured and defined as “true values.” In each study, the same bone was imaged using computed tomography, measured with this software, and the measurement error from the corresponding “true values” was calculated. Results: Study 1: The mean diameter of the same marker using the 3DMI was 23.951 ± 0.055 mm. Comparisons between measurements using the 3DMI and this software revealed that the mean error in length was <0.3 mm, and the error in angle was <0.25°. Study 2: In the bones adjusted to the retrocondylar plane with the 3DMI and this software, the average error in the distance from the planes to each marker was 0.43 (0.32–0.58) mm. Conclusion: This surgical planning software could measure the distance and angle between the centers of the markers with high accuracy; therefore, this is very useful for pre- and postoperative evaluation.