Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Development of chopper-stabilized ASIC preamplifier for improving noise equivalent magnetic induction of search coil magnetometer probing space plasma waves
by
Ozaki, Mitsunori
, Tokunaga, Yuya
, Yagitani, Satoshi
, Koji, Hiroki
in
Application specific integrated circuits
/ Coils
/ Cutting
/ Cyclotrons
/ Electromagnetic induction
/ Equivalence
/ Ion cyclotron waves
/ Low noise
/ Low temperature
/ Magnetic fields
/ Magnetic induction
/ Magnetometers
/ Magnetospheres
/ Magnetospheric dynamics
/ Plasma
/ Plasma waves
/ Power consumption
/ Preamplifiers
/ Radiation
/ Radiation tolerance
/ Space plasmas
/ Temperature dependence
/ Waves
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Development of chopper-stabilized ASIC preamplifier for improving noise equivalent magnetic induction of search coil magnetometer probing space plasma waves
by
Ozaki, Mitsunori
, Tokunaga, Yuya
, Yagitani, Satoshi
, Koji, Hiroki
in
Application specific integrated circuits
/ Coils
/ Cutting
/ Cyclotrons
/ Electromagnetic induction
/ Equivalence
/ Ion cyclotron waves
/ Low noise
/ Low temperature
/ Magnetic fields
/ Magnetic induction
/ Magnetometers
/ Magnetospheres
/ Magnetospheric dynamics
/ Plasma
/ Plasma waves
/ Power consumption
/ Preamplifiers
/ Radiation
/ Radiation tolerance
/ Space plasmas
/ Temperature dependence
/ Waves
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Development of chopper-stabilized ASIC preamplifier for improving noise equivalent magnetic induction of search coil magnetometer probing space plasma waves
by
Ozaki, Mitsunori
, Tokunaga, Yuya
, Yagitani, Satoshi
, Koji, Hiroki
in
Application specific integrated circuits
/ Coils
/ Cutting
/ Cyclotrons
/ Electromagnetic induction
/ Equivalence
/ Ion cyclotron waves
/ Low noise
/ Low temperature
/ Magnetic fields
/ Magnetic induction
/ Magnetometers
/ Magnetospheres
/ Magnetospheric dynamics
/ Plasma
/ Plasma waves
/ Power consumption
/ Preamplifiers
/ Radiation
/ Radiation tolerance
/ Space plasmas
/ Temperature dependence
/ Waves
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Development of chopper-stabilized ASIC preamplifier for improving noise equivalent magnetic induction of search coil magnetometer probing space plasma waves
Journal Article
Development of chopper-stabilized ASIC preamplifier for improving noise equivalent magnetic induction of search coil magnetometer probing space plasma waves
2023
Request Book From Autostore
and Choose the Collection Method
Overview
Space-based search coil (SC) magnetometers connected to preamplifiers have been used to investigate magnetic field vectors of plasma waves from 100 mHz to 10 kHz for understanding magnetospheric dynamics. However, flicker noise below several 100 Hz of typical preamplifiers degrades the noise equivalent magnetic induction (NEMI) of SCs and affects the probing of plasma waves from 100 mHz to 100 Hz. In this study, we developed a chopper-stabilized preamplifier using application-specific integrated circuit (ASIC) technology for improving the NEMI below 100 Hz while maintaining miniaturization and a low power consumption. The chopper ASIC preamplifier fits into a layout size of 2.3 × 3.4 mm in a bare chip. We used two SC sensors with different (20 cm and 5 cm) lengths to evaluate the NEMI with the prototype of the chopper ASIC preamplifier. At 100 mHz, the NEMI values of the 20-cm length and 5-cm length SCs were 0.1 nT/Hz1/2 and 1.9 nT/Hz1/2, respectively, which can detect typical electromagnetic ion cyclotron waves in the magnetosphere. The NEMI value at 100 mHz for the 5-cm-length SC was improved by approximately 19 dB compared with that for a previous ASIC preamplifier without chopping. We conducted temperature tests for the chopper ASIC preamplifier to evaluate the behavior for under a wide temperature range from − 40 to + 100 °C. The temperature coefficient of the gain was approximately − 0.02 dB/°C, which is a sufficiently low temperature-dependence. The use of ASIC technology achieved high stability under the wide temperature range and radiation tolerance. Thus, the chopper ASIC preamplifier with high robustness and ultra-low noise characteristics is suitable for plasma wave observations in harsh space environments for future missions.
Publisher
Springer Nature B.V
Subject
This website uses cookies to ensure you get the best experience on our website.