Impact of the amount of liquid intake on the dose rate of patients treated with radioiodine
by
Banani, Aida
, Haghighatafshar, Mahdi
, Zeinali-Rafsanjani, Banafsheh
, Etemadi, Zahra
, Ghaedian, Tahereh
in
Caffeine
/ Cancer
/ Cancer patients
/ Cancer therapies
/ Care and treatment
/ Drinking water
/ Drug dosages
/ Gamma rays
/ Guidelines
/ Iodine
/ Iodine 131
/ Mathematical analysis
/ Metabolism
/ Metastasis
/ Nuclear medicine
/ Original
/ Patients
/ Radiation (Physics)
/ Radiation dosage
/ Radiation therapy
/ Research centers
/ Teaching hospitals
/ Thyroid cancer
/ Urine
2018
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Impact of the amount of liquid intake on the dose rate of patients treated with radioiodine
by
Banani, Aida
, Haghighatafshar, Mahdi
, Zeinali-Rafsanjani, Banafsheh
, Etemadi, Zahra
, Ghaedian, Tahereh
in
Caffeine
/ Cancer
/ Cancer patients
/ Cancer therapies
/ Care and treatment
/ Drinking water
/ Drug dosages
/ Gamma rays
/ Guidelines
/ Iodine
/ Iodine 131
/ Mathematical analysis
/ Metabolism
/ Metastasis
/ Nuclear medicine
/ Original
/ Patients
/ Radiation (Physics)
/ Radiation dosage
/ Radiation therapy
/ Research centers
/ Teaching hospitals
/ Thyroid cancer
/ Urine
2018
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Impact of the amount of liquid intake on the dose rate of patients treated with radioiodine
by
Banani, Aida
, Haghighatafshar, Mahdi
, Zeinali-Rafsanjani, Banafsheh
, Etemadi, Zahra
, Ghaedian, Tahereh
in
Caffeine
/ Cancer
/ Cancer patients
/ Cancer therapies
/ Care and treatment
/ Drinking water
/ Drug dosages
/ Gamma rays
/ Guidelines
/ Iodine
/ Iodine 131
/ Mathematical analysis
/ Metabolism
/ Metastasis
/ Nuclear medicine
/ Original
/ Patients
/ Radiation (Physics)
/ Radiation dosage
/ Radiation therapy
/ Research centers
/ Teaching hospitals
/ Thyroid cancer
/ Urine
2018
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Impact of the amount of liquid intake on the dose rate of patients treated with radioiodine
Journal Article
Impact of the amount of liquid intake on the dose rate of patients treated with radioiodine
2018
Request Book From Autostore
and Choose the Collection Method
Overview
Purpose: Despite therapeutic effects of radioiodine in patients with differentiated thyroid cancer, there are some disadvantages due to harmful radiation to other tissues. According to the current guidelines, patients are recommended to drink lots of water and frequent voiding to reduce the amount of 131I in the body. This study was designed to assess the impact of the amount of liquid intake on reduction of the measured dose rate of radioiodine-treated patients. Materials and Methods: A total of 42 patients with differentiated thyroid cancer without metastasis who had undergone total thyroidectomy and had been treated with radioiodine were selected. The patients were divided into two groups according to the amount of their fluid intake which was measured during the first 48 h after 131I administration. In all patients, the dose rate was measured immediately and 48 h after iodine administration. Results: Each group included 21 patients. Dose rate ratio (the ratio of the second dose rate to the first dose rate) and dose rate difference ratio (the ratio of the difference between the two measured dose rates to the first dose rate) were calculated for each patient. Despite the significant difference in the amount of the liquid drunk, no statistically significant difference was seen between the different groups in parameters of dose-rate ratio and dose-rate difference ratio. Conclusion: Higher fluid intake (>60 ml/h in our study) alone would not effectively reduce the patient's radiation dose rate at least not more than a well-hydrated state. It seems that other interfering factors in the thyroidectomized patients may also have some impacts on this physiologic process.