Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
The Effects of a Biomimetic Hybrid Meso- and Nano-Scale Surface Topography on Blood and Protein Recruitment in a Computational Fluid Dynamics Implant Model
by
Kitajima, Hiroaki
, Hirota, Makoto
, Mitsudo, Kenji
, Ogawa, Takahiro
, Iwai, Toshinori
, Osawa, Kohei
, Saruta, Juri
in
Biomimetics
/ Blood
/ bone-implant integration
/ computational fluid dynamics (CFD)
/ Computer applications
/ Fibrinogen
/ Fluid dynamics
/ Laser etching
/ Microenvironments
/ Morphology
/ Osseointegration
/ Proteins
/ Quantitative analysis
/ Scanning electron microscopy
/ Titanium alloys
/ titanium implant
/ Topography
/ Transplants & implants
/ zirconia implant
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
The Effects of a Biomimetic Hybrid Meso- and Nano-Scale Surface Topography on Blood and Protein Recruitment in a Computational Fluid Dynamics Implant Model
by
Kitajima, Hiroaki
, Hirota, Makoto
, Mitsudo, Kenji
, Ogawa, Takahiro
, Iwai, Toshinori
, Osawa, Kohei
, Saruta, Juri
in
Biomimetics
/ Blood
/ bone-implant integration
/ computational fluid dynamics (CFD)
/ Computer applications
/ Fibrinogen
/ Fluid dynamics
/ Laser etching
/ Microenvironments
/ Morphology
/ Osseointegration
/ Proteins
/ Quantitative analysis
/ Scanning electron microscopy
/ Titanium alloys
/ titanium implant
/ Topography
/ Transplants & implants
/ zirconia implant
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
The Effects of a Biomimetic Hybrid Meso- and Nano-Scale Surface Topography on Blood and Protein Recruitment in a Computational Fluid Dynamics Implant Model
by
Kitajima, Hiroaki
, Hirota, Makoto
, Mitsudo, Kenji
, Ogawa, Takahiro
, Iwai, Toshinori
, Osawa, Kohei
, Saruta, Juri
in
Biomimetics
/ Blood
/ bone-implant integration
/ computational fluid dynamics (CFD)
/ Computer applications
/ Fibrinogen
/ Fluid dynamics
/ Laser etching
/ Microenvironments
/ Morphology
/ Osseointegration
/ Proteins
/ Quantitative analysis
/ Scanning electron microscopy
/ Titanium alloys
/ titanium implant
/ Topography
/ Transplants & implants
/ zirconia implant
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
The Effects of a Biomimetic Hybrid Meso- and Nano-Scale Surface Topography on Blood and Protein Recruitment in a Computational Fluid Dynamics Implant Model
Journal Article
The Effects of a Biomimetic Hybrid Meso- and Nano-Scale Surface Topography on Blood and Protein Recruitment in a Computational Fluid Dynamics Implant Model
2023
Request Book From Autostore
and Choose the Collection Method
Overview
The mechanisms underlying bone-implant integration, or osseointegration, are still incompletely understood, in particular how blood and proteins are recruited to implant surfaces. The objective of this study was to visualize and quantify the flow of blood and the model protein fibrinogen using a computational fluid dynamics (CFD) implant model. Implants with screws were designed with three different surface topographies: (1) amorphous, (2) nano-trabecular, and (3) hybrid meso-spikes and nano-trabeculae. The implant with nano-topography recruited more blood and fibrinogen to the implant interface than the amorphous implant. Implants with hybrid topography further increased recruitment, with particularly efficient recruitment from the thread area to the interface. Blood movement significantly slowed at the implant interface compared with the thread area for all implants. The blood velocity at the interface was 3- and 4-fold lower for the hybrid topography compared with the nano-topography and amorphous surfaces, respectively. Thus, this study for the first time provides insights into how different implant surfaces regulate blood dynamics and the potential advantages of surface texturization in blood and protein recruitment and retention. In particular, co-texturization with a hybrid meso- and nano-topography created the most favorable microenvironment. The established CFD model is simple, low-cost, and expected to be useful for a wide range of studies designing and optimizing implants at the macro and micro levels.
Publisher
MDPI AG,MDPI
Subject
This website uses cookies to ensure you get the best experience on our website.