Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
How reproducible are clinical measurements in robotic knee surgery?
by
Matassi, Fabrizio
, Innocenti, Bernardo
, Giabbani, Niccolò
, Civinini, Roberto
, Bori, Edoardo
in
In vivo measurements
/ Joint surgery
/ Knee
/ Knee surgery
/ Medicine
/ Medicine & Public Health
/ Original Paper
/ Orthopedics
/ Reproducibility
/ Robotic surgery
/ Surgical Orthopedics
/ Variability
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
How reproducible are clinical measurements in robotic knee surgery?
by
Matassi, Fabrizio
, Innocenti, Bernardo
, Giabbani, Niccolò
, Civinini, Roberto
, Bori, Edoardo
in
In vivo measurements
/ Joint surgery
/ Knee
/ Knee surgery
/ Medicine
/ Medicine & Public Health
/ Original Paper
/ Orthopedics
/ Reproducibility
/ Robotic surgery
/ Surgical Orthopedics
/ Variability
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
How reproducible are clinical measurements in robotic knee surgery?
by
Matassi, Fabrizio
, Innocenti, Bernardo
, Giabbani, Niccolò
, Civinini, Roberto
, Bori, Edoardo
in
In vivo measurements
/ Joint surgery
/ Knee
/ Knee surgery
/ Medicine
/ Medicine & Public Health
/ Original Paper
/ Orthopedics
/ Reproducibility
/ Robotic surgery
/ Surgical Orthopedics
/ Variability
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
How reproducible are clinical measurements in robotic knee surgery?
Journal Article
How reproducible are clinical measurements in robotic knee surgery?
2023
Request Book From Autostore
and Choose the Collection Method
Overview
Purpose
Robotic-assisted surgery has been recently introduced to improve biomechanical restoration, and thus better clinical and functional outcomes, after knee joint arthroplasty operations. Robotic-assisted uni-compartmental knee arthroplasty (UKA) aims indeed to improve surgical bone resection and alignment accuracy, optimized component positioning and knee balancing, relying on a series of calibration measurements performed during the surgery. These advantages focus therefore on improving the reproducibility of UKA surgeries, reducing (if not eliminating) eventual differences among high- and low-volume surgeons.
The purpose of this study is to investigate and quantify the reproducibility of in-vivo measurements performed with a robotic system: the intra- and inter-observer variability of a series of measurements was therefore analyzed and compared among differently experienced operators.
Methods
Five patients were analyzed and underwent robotic-assisted UKA using a semi-active robotic system.
Three different observers with different experience levels were involved to independently perform the measurements of two parameters of the preoperative knee (Hip-Knee-Ankle angle [HKAa], Internal-External Rotation) at different degrees of knee flexion. Inter-observer and intra-observer comparisons were performed.
Results
The average variability in the measurements obtained from the intra-observer and inter-observer comparisons were always < 0.68° for HKAa and < 2.59° for internal-external rotation, and the ICCs showed excellent agreement (> 0.75) for most cases and good agreement (> 0.60) in the remaining ones.
Conclusion
This study demonstrated high reproducibility of the measurements obtainable in clinical environment with the robotic system. The inter-observer results furthermore showed that the level of confidence with the robotic system is not significantly influencing the measurement.