Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Gaps in the evidence underpinning high-risk medical devices in Europe at market entry, and potential solutions
by
Primus-de Jong, Célia
, Neyt, Mattias
, Hulstaert, Frank
, Pouppez, Céline
, Harkin, Kathleen
in
CE marking
/ Comparator
/ Compliance
/ Conformity
/ Decision making
/ Declaration of Helsinki
/ Ethics
/ Evidence gaps
/ FDA approval
/ Feedback
/ Health care industry
/ Health technology assessment
/ Human Genetics
/ Legislation
/ Literature reviews
/ Management
/ Market entry
/ Medical care
/ Medical device industry
/ Medical devices
/ Medical equipment
/ Medical equipment and supplies industry
/ Medical innovations
/ Medical research
/ Medical technology
/ Medical test kit industry
/ Medicine
/ Medicine & Public Health
/ MedTech Innovation & Rare Diseases
/ Other
/ Patients
/ Pharmacology/Toxicology
/ Position Statement
/ Quality management
/ Quality of life
/ Rare diseases
/ Regulation
/ Reimbursement
/ Technology assessment
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Gaps in the evidence underpinning high-risk medical devices in Europe at market entry, and potential solutions
by
Primus-de Jong, Célia
, Neyt, Mattias
, Hulstaert, Frank
, Pouppez, Céline
, Harkin, Kathleen
in
CE marking
/ Comparator
/ Compliance
/ Conformity
/ Decision making
/ Declaration of Helsinki
/ Ethics
/ Evidence gaps
/ FDA approval
/ Feedback
/ Health care industry
/ Health technology assessment
/ Human Genetics
/ Legislation
/ Literature reviews
/ Management
/ Market entry
/ Medical care
/ Medical device industry
/ Medical devices
/ Medical equipment
/ Medical equipment and supplies industry
/ Medical innovations
/ Medical research
/ Medical technology
/ Medical test kit industry
/ Medicine
/ Medicine & Public Health
/ MedTech Innovation & Rare Diseases
/ Other
/ Patients
/ Pharmacology/Toxicology
/ Position Statement
/ Quality management
/ Quality of life
/ Rare diseases
/ Regulation
/ Reimbursement
/ Technology assessment
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Gaps in the evidence underpinning high-risk medical devices in Europe at market entry, and potential solutions
by
Primus-de Jong, Célia
, Neyt, Mattias
, Hulstaert, Frank
, Pouppez, Céline
, Harkin, Kathleen
in
CE marking
/ Comparator
/ Compliance
/ Conformity
/ Decision making
/ Declaration of Helsinki
/ Ethics
/ Evidence gaps
/ FDA approval
/ Feedback
/ Health care industry
/ Health technology assessment
/ Human Genetics
/ Legislation
/ Literature reviews
/ Management
/ Market entry
/ Medical care
/ Medical device industry
/ Medical devices
/ Medical equipment
/ Medical equipment and supplies industry
/ Medical innovations
/ Medical research
/ Medical technology
/ Medical test kit industry
/ Medicine
/ Medicine & Public Health
/ MedTech Innovation & Rare Diseases
/ Other
/ Patients
/ Pharmacology/Toxicology
/ Position Statement
/ Quality management
/ Quality of life
/ Rare diseases
/ Regulation
/ Reimbursement
/ Technology assessment
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Gaps in the evidence underpinning high-risk medical devices in Europe at market entry, and potential solutions
Journal Article
Gaps in the evidence underpinning high-risk medical devices in Europe at market entry, and potential solutions
2023
Request Book From Autostore
and Choose the Collection Method
Overview
Aim
To determine the level of evidence for innovative high-risk medical devices at market entry.
Methods
We reviewed all Belgian healthcare payer (RIZIV-INAMI) assessor reports on novel implants or invasive medical devices (n = 18, Class IIb-III) available between 2018 to mid-2019 on applications submitted for inclusion on their reimbursement list. We also conducted a review of the literature on evidence gaps and an analysis of relevant legal and ethical frameworks within the European context.
Findings
Conformity assessment of medical devices is based on performance, safety, and an acceptable risk-benefit balance. Information submitted for obtaining CE marking is confidential and legally protected, limiting access to clinical evidence. Seven out of the 18 RIZIV-INAMI assessor reports (39%) included a randomized controlled trial (RCT) using the novel device, whilst 2 applications (11%) referred to an RCT that used a different device. The population included was inappropriate or unclear for 3 devices (17%). Only half of the applications presented evidence on quality of life or functioning and 2 (11%) presented overall survival data. Four applications (22%) included no data beyond twelve months. The findings from the literature demonstrated similar problems with the study design and the clinical evidence.
Discussion and conclusions
CE marking does not indicate that a device is effective, only that it complies with the law. The lack of transparency hampers evidence-based decision making. Despite greater emphasis on clinical benefit for the patient, the provisions of the European Medical Device Regulation (MDR) are not yet fully aligned with international ethical standards for clinical research. The MDR fails to address key issues, such as the lack of access to data submitted for CE marking and a failure to require evidence of clinical effectiveness. Indeed, a first report shows no improvement in the clinical evidence for implantable devices generated under the MDR. Thus, patients may continue to be exposed to ineffective or unsafe novel devices. The Health Technology Assessment Regulation plans for Joint Scientific Consultations for specific high-risk devices before companies begin their pivotal clinical investigations. The demanded comparative evidence should facilitate payer decisions. Nevertheless, there is also a need for legislation requiring comparative RCTs assessing patient-relevant outcomes for high-risk devices to ensure implementation, including development and implementation of common specifications for study designs.