MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Mechanical and thermal efficiency of a single drill system for bone-anchored hearing implants
Mechanical and thermal efficiency of a single drill system for bone-anchored hearing implants
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Mechanical and thermal efficiency of a single drill system for bone-anchored hearing implants
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Mechanical and thermal efficiency of a single drill system for bone-anchored hearing implants
Mechanical and thermal efficiency of a single drill system for bone-anchored hearing implants

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Mechanical and thermal efficiency of a single drill system for bone-anchored hearing implants
Mechanical and thermal efficiency of a single drill system for bone-anchored hearing implants
Journal Article

Mechanical and thermal efficiency of a single drill system for bone-anchored hearing implants

2025
Request Book From Autostore and Choose the Collection Method
Overview
This study aimed to evaluate the mechanical performance, heat generation, bone distortion, and characteristics of bone chips generated during drilling using a novel one-step guided drill system (MONO) for installing the bone-anchored hearing system (BAHS). A comparison was made with an existing three-stage drill system (MIPS). Drill force and torque were measured during drilling in cow tibia at different feed rates. Compact artificial bone was utilized to determine temperature increases using thermocouples placed at specific positions around the osteotomy site during drilling with the two systems at different feed rates and levels of irrigation. The effects of drilling on osteotomy characteristics and the formation of bone fragments were evaluated through micro-CT, Raman spectroscopy, and histology. Force and torque increased with the feed rate in both systems, whereas the total work required to perform the osteotomy significantly decreased as the feed rate increased. Compared to the three-stage MIPS system, the MONO system required less work for one-step osteotomy creation, generated equal or less heat, and exhibited greater tolerance for procedural deviations in irrigation and drilling sequence. Additionally, heat generation for both systems decreased when drilling at higher feed rates. Compositional changes within the osteotomy were primarily observed under reduced irrigation protocols, while no differences were identified in bone chips across drilling protocols. Compared with a multistep conventional drilling procedure, MONO drilling is less affected by variations in the drilling protocol, particularly in flapless and blind procedures, resulting in safer and more efficient osteotomy creation. The MONO system demonstrated superior performance in terms of energy efficiency and temperature control.