MbrlCatalogueTitleDetail

Do you wish to reserve the book?
The accuracy of computed tomography scans for rapid prototyping of canine skulls
The accuracy of computed tomography scans for rapid prototyping of canine skulls
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
The accuracy of computed tomography scans for rapid prototyping of canine skulls
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
The accuracy of computed tomography scans for rapid prototyping of canine skulls
The accuracy of computed tomography scans for rapid prototyping of canine skulls

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
The accuracy of computed tomography scans for rapid prototyping of canine skulls
The accuracy of computed tomography scans for rapid prototyping of canine skulls
Journal Article

The accuracy of computed tomography scans for rapid prototyping of canine skulls

2019
Request Book From Autostore and Choose the Collection Method
Overview
This study's objective was to determine the accuracy of using current computed tomography (CT) scan and software techniques for rapid prototyping by quantifying the margin of error between CT models and laser scans of canine skull specimens. Twenty canine skulls of varying morphology were selected from an anatomy collection at a veterinary school. CT scans (bone and standard algorithms) were performed for each skull, and data segmented (testing two lower threshold settings of 226HU and -650HU) into 3-D CT models. Laser scans were then performed on each skull. The CT models were compared to the corresponding laser scan to determine the error generated from the different types of CT model parameters. This error was then compared between the different types of CT models to determine the most accurate parameters. The mean errors for the 226HU CT models, both bone and standard algorithms, were not significant from zero error (p = 0.1076 and p = 0.0580, respectively). The mean errors for both -650HU CT models were significant from zero error (p < 0.001). Significant differences were detected between CT models for 3 CT model comparisons: Bone (p < 0.0001); Standard (p < 0.0001); and -650HU (p < 0.0001). For 226HU CT models, a significant difference was not detected between CT models (p = 0.2268). Independent of the parameters tested, the 3-D models derived from CT imaging accurately represent the real skull dimensions, with CT models differing less than 0.42 mm from the real skull dimensions. The 226HU threshold was more accurate than the -650HU threshold. For the 226HU CT models, accuracy was not dependent on the CT algorithm. For the -650 CT models, bone was more accurate than standard algorithms. Knowing the inherent error of this procedure is important for use in 3-D printing for surgical planning and medical education.