MbrlCatalogueTitleDetail

Do you wish to reserve the book?
First Evaluation of Ultrafast Ultrasound Coupled With Phrenic Stimulation for Noninvasive Diagnosis of Diaphragm Dysfunction
First Evaluation of Ultrafast Ultrasound Coupled With Phrenic Stimulation for Noninvasive Diagnosis of Diaphragm Dysfunction
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
First Evaluation of Ultrafast Ultrasound Coupled With Phrenic Stimulation for Noninvasive Diagnosis of Diaphragm Dysfunction
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
First Evaluation of Ultrafast Ultrasound Coupled With Phrenic Stimulation for Noninvasive Diagnosis of Diaphragm Dysfunction
First Evaluation of Ultrafast Ultrasound Coupled With Phrenic Stimulation for Noninvasive Diagnosis of Diaphragm Dysfunction

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
First Evaluation of Ultrafast Ultrasound Coupled With Phrenic Stimulation for Noninvasive Diagnosis of Diaphragm Dysfunction
First Evaluation of Ultrafast Ultrasound Coupled With Phrenic Stimulation for Noninvasive Diagnosis of Diaphragm Dysfunction
Journal Article

First Evaluation of Ultrafast Ultrasound Coupled With Phrenic Stimulation for Noninvasive Diagnosis of Diaphragm Dysfunction

2026
Request Book From Autostore and Choose the Collection Method
Overview
Background Diaphragm dysfunction is an important and often unrecognized cause of dyspnea. The current gold standard, transdiaphragmatic twitch pressure (Pdi,tw), requires oesophageal and gastric balloon catheters and is infrequently used in routine care. We evaluated whether ultrafast ultrasound descriptors of costal diaphragm during bilateral phrenic magnetic stimulation can provide a noninvasive alternative for assessing diaphragm contractility. Methods Thirty patients (19 men and 11 women) referred for suspected diaphragm dysfunction (median age 57 [42–63] years) underwent bilateral anterolateral magnetic stimulation with simultaneous ultrafast ultrasound and oesophageal/gastric pressure recordings. Peak diaphragm tissue velocity, acceleration and jerk were extracted. Associations with Pdi,tw were assessed using ridge regression. Diagnostic performance for detecting abnormal Pdi,tw (< 20 cmH2O) was evaluated using Bayesian receiver operating characteristic (ROC) analysis, including posterior mean AUC and 95% credible intervals. Agreement between predicted and measured Pdi,tw was assessed using Lin's concordance correlation coefficient and Passing–Bablok regression. Results Twenty four of 30 patients (80%) had abnormal Pdi,tw. Ultrafast ultrasound descriptors correlated with Pdi,tw (Spearman's ρ: velocity 0.77 [95% CI, 0.57–0.89], acceleration 0.70 [95% CI, 0.41–0.87], jerk 0.67 [95% CI, 0.43–0.85]; all p < 0.0001). The multivariable ridge model explained 66% of the variance in Pdi,tw and showed high agreement with measured values (Lin's concordance correlation coefficient = 0.87 [95% CI, 0.75–0.93]). Bayesian ROC analysis demonstrated strong discrimination of diaphragm dysfunction (AUC = 0.91; 95% credible interval [CrI], 0.76–0.98). Using the clinical threshold of 20 cmH2O, model‐predicted Pdi,tw yielded a sensitivity of 75% and specificity of 100%. The optimal velocity threshold for discriminating abnormal Pdi,tw was 10.25 mm·ms−1 (95% CrI, 6.12–18.58 mm·ms−1). The corresponding thresholds for acceleration and jerk were 408.6 mm·ms−2 (95% CrI, 122.6–952.4) and 3073 mm·ms−3 (95% CrI, 1038.8–11541.4), respectively. Conclusions Ultrafast ultrasound coupled with magnetic phrenic stimulation provides a feasible, noninvasive, nonvolitional assessment of diaphragm contractility. Diaphragm motion descriptors reliably predicted Pdi,tw and enabled accurate identification of diaphragm dysfunction. These findings support further clinical evaluation and warrant larger multicentre validation studies.