Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Standardized reduction and palmar plating of dorsally displaced distal radius fractures for safe and atraumatic reconstruction of the anatomy of the radius
by
Kiesel, Sebastian
, Löw, Steffen
in
Bone Plates
/ Bone Screws
/ Female
/ Fracture Fixation, Internal - instrumentation
/ Fracture Fixation, Internal - methods
/ Humans
/ Male
/ Radius Fractures - diagnostic imaging
/ Radius Fractures - surgery
/ Treatment Outcome
/ Wrist Fractures - diagnostic imaging
/ Wrist Fractures - surgery
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Standardized reduction and palmar plating of dorsally displaced distal radius fractures for safe and atraumatic reconstruction of the anatomy of the radius
by
Kiesel, Sebastian
, Löw, Steffen
in
Bone Plates
/ Bone Screws
/ Female
/ Fracture Fixation, Internal - instrumentation
/ Fracture Fixation, Internal - methods
/ Humans
/ Male
/ Radius Fractures - diagnostic imaging
/ Radius Fractures - surgery
/ Treatment Outcome
/ Wrist Fractures - diagnostic imaging
/ Wrist Fractures - surgery
2024
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Standardized reduction and palmar plating of dorsally displaced distal radius fractures for safe and atraumatic reconstruction of the anatomy of the radius
by
Kiesel, Sebastian
, Löw, Steffen
in
Bone Plates
/ Bone Screws
/ Female
/ Fracture Fixation, Internal - instrumentation
/ Fracture Fixation, Internal - methods
/ Humans
/ Male
/ Radius Fractures - diagnostic imaging
/ Radius Fractures - surgery
/ Treatment Outcome
/ Wrist Fractures - diagnostic imaging
/ Wrist Fractures - surgery
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Standardized reduction and palmar plating of dorsally displaced distal radius fractures for safe and atraumatic reconstruction of the anatomy of the radius
Journal Article
Standardized reduction and palmar plating of dorsally displaced distal radius fractures for safe and atraumatic reconstruction of the anatomy of the radius
2024
Request Book From Autostore
and Choose the Collection Method
Overview
Standardization of palmar plate osteosynthesis in order to consequently achieve physiologic anatomy of the distal radius end.
Unstable dorsally displaced distal radius fractures or fractures that should be treated functionally.
Severe intraarticular joint depression that cannot be reduced with either a palmar or arthroscopic assisted approach.
Patient in supine position with the forearm supinated on arm table. Radiopalmar incision along the radial border of the flexor carpi radialis tendon. Detachment of the pronator quadratus muscle from radial to ulnar. Gross reduction with eventual correction of a dorsal or radial shift. Placement of the angular stable plate and preliminary fixation with a nonangular stable cortical screw in the long hole at the radius shaft. Fluoroscopic control of axial alignment in the anteroposterior view and of correct distal position of the plate in the lateral view under reduction condition. Placement of one or two angular stable screws at the shaft. Under subtle reduction with flexion, ulnar deviation and axial traction placement of two K‑wires via the holes at the distal edge of the plate. These wires mostly keep reduction maintained while reduction maneuver can be paused. Fluoroscopic control in two planes. Replacement of the wires by distal angular stable screws with the help of the wires as an orientation. In case of insufficient reduction, reduction maneuver can be repeated while the first angular stable screw is locked. Final fluoroscopic control in two planes and ulnar deviation, eventually also in tangential view and clinical testing for stability of the distal radioulnar joint. Wound closure only by skin suture. Application of a sterile dressing and a palmar cast.
Arm consequently in upright position and active and complete movement of fingers. Palmar below-elbow cast for 2 weeks, then movement of wrist without exertion. After regular radiographic control 4-5 weeks postoperatively, increase of axial load to normal and, if needed, physiotherapy. Clinical control for irritation of tendons by plate or screws after 1 year and eventual plate removal.
Subject