Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
11 result(s) for "Bița, Ana-Iulia"
Sort by:
Chitosan-Based Biomaterials for Hemostatic Applications: A Review of Recent Advances
Hemorrhage is a detrimental event present in traumatic injury, surgery, and disorders of bleeding that can become life-threatening if not properly managed. Moreover, uncontrolled bleeding can complicate surgical interventions, altering the outcome of surgical procedures. Therefore, to reduce the risk of complications and decrease the risk of morbidity and mortality associated with hemorrhage, it is necessary to use an effective hemostatic agent that ensures the immediate control of bleeding. In recent years, there have been increasingly rapid advances in developing a novel generation of biomaterials with hemostatic properties. Nowadays, a wide array of topical hemostatic agents is available, including chitosan-based biomaterials that have shown outstanding properties such as antibacterial, antifungal, hemostatic, and analgesic activity in addition to their biocompatibility, biodegradability, and wound-healing effects. This review provides an analysis of chitosan-based hemostatic biomaterials and discusses the progress made in their performance, mechanism of action, efficacy, cost, and safety in recent years.
Fluoride Treatment and In Vitro Corrosion Behavior of Mg-Nd-Y-Zn-Zr Alloys Type
Fluoride conversion coatings on Mg present many advantages, among which one can find the reduction of the corrosion rate under “in vivo” or “in vitro” conditions and the promotion of the calcium phosphate deposition. Moreover, the fluoride ions released from MgF2 do not present cytotoxic effects and inhibit the biofilm formation, and thus these treated alloys are very suitable for cardiovascular stents and biodegradable orthopedic implants. In this paper, the biodegradation behavior of four new magnesium biodegradable alloys that have been developed in the laboratory conditions, before and after surface modifications by fluoride conversion (and sandblasting) coatings, are analyzed. We performed structural and surface analysis (XRD, SEM, contact angle) before and after applying different surface treatments. Furthermore, we studied the electrochemical behavior and biodegradation of all experimental samples after immersion test performed in NaCl solution. For a better evaluation, we also used LM and SEM for evaluation of the corroded samples after immersion test. The results showed an improved corrosion resistance for HF treated alloy in the NaCl solution. The chemical composition, uniformity, thickness and stability of the layers generated on the surface of the alloys significantly influence their corrosion behavior. Our study reveals that HF treatment is a beneficial way to improve the biofunctional properties required for the studied magnesium alloys to be used as biomaterials for manufacturing the orthopedic implants.
Essential Oils as Antimicrobial Active Substances in Wound Dressings
Wound dressings for skin lesions, such as bedsores or pressure ulcers, are widely used for many patients, both during hospitalization and in subsequent treatment at home. To improve the treatment and shorten the healing time and, therefore, the cost, numerous types of wound dressings have been developed by manufacturers. Considering certain inconveniences related to the intolerance of some patients to antibiotics and the antimicrobial, antioxidant, and curative properties of certain essential oils, we conducted research by incorporating these oils, based on polyvinyl alcohol/ polyvinyl pyrrolidone (PVA/PVP) biopolymers, into dressings. The objective of this study was to study the potential of a polymeric matrix for wound healing, with polyvinyl alcohol as the main material and polyvinyl pyrrolidone and hydroxypropyl methylcellulose (HPMC) as secondary materials, together with additives (plasticizers poly(ethylene glycol) (PEG) and glycerol), stabilizers (Zn stearate), antioxidants (vitamin A and vitamin E), and four types of essential oils (fennel, peppermint, pine, and thyme essential oils). For all the studied samples, the combining compatibility, antimicrobial, and cytotoxicity properties were investigated. The obtained results demonstrated a uniform morphology for almost all the samples and adequate barrier properties for contact with suppurating wounds. The results show that the obtained samples containing essential oils have a good inhibitory effect on, or antimicrobial properties against, Staphylococcus aureus ATCC 25923, Enterococcus faecalis ATCC 29212, Escherichia coli ATCC 25922, Pseudomonas aeruginosa ATCC 27853, and Candida albicans ATCC 10231. The MTT assay showed that the tested samples were not toxic and did not lead to cell death. The results showed that the essential oils used provide an effective solution as active substances in wound dressings.
Failure Analysis of Ultra-High Molecular Weight Polyethylene Tibial Insert in Total Knee Arthroplasty
Knee osteoarthritis is treated based on total knee arthroplasty (TKA) interventions. The most frequent failure cause identified in surgical practice is due to wear and oxidation processes of the prothesis’ tibial insert. This component is usually manufactured from ultra-high molecular weight polyethylene (UHMWPE). To estimate the clinical complications related to a specific prosthesis design, we investigated four UHMWPE tibial inserts retrieved from patients from Clinical Hospital Colentina, Bucharest, Romania. For the initial analysis of the polyethylene degradation modes, macrophotography was chosen. A light stereomicroscope was used to estimate the structural performance and the implant surface degradation. Scanning electron microscopy confirmed the optical results and fulfilled the computation of the Hood index. The oxidation process in UHMWPE was analyzed based on Fourier-transform infrared spectroscopy (FTIR). The crystallinity degree and the oxidation index were computed in good agreement with the existing standards. Mechanical characterization was conducted based on the small punch test. The elastic modulus, initial peak load, ultimate load, and ultimate displacement were estimated. Based on the aforementioned experimental tests, a variation between 9 and 32 was found in the case of the Hood score. The oxidation index has a value of 1.33 for the reference sample and a maximum of 9.78 for a retrieved sample.
Electrochemical and In Vitro Biological Evaluation of Bio-Active Coatings Deposited by Magnetron Sputtering onto Biocompatible Mg-0.8Ca Alloy
The use of resorbable magnesium alloys in the design of implants represents a new direction in the healthcare domain. Two main research avenues are currently explored for developing or improving metallic biomaterials: (i) increase of their corrosion resistance by designed compositional and structural modifications, and (ii) functionalization of their surfaces by coating with ceramic or polymeric layers. The main objective of this work was to comparatively assess bio-functional coatings (i.e., highly-crystallized hydroxyapatite and silica-rich glass) deposited by radio-frequency magnetron sputtering (RF-MS) on a biodegradable Mg-0.8Ca alloy (0.8 wt.% of Ca). After probing their morphology (by scanning electron microscopy) and structure (by Fourier transform infrared spectroscopy and grazing incidence X-ray diffraction), the corrosion resistance of the RF-MS coated Mg-0.8Ca substrates was electrochemically tested (in synthetic biological media with different degrees of biomimicry), and their cytocompatibility was assessed in osteoblast and fibroblast cell cultures. By collective assessment, the most promising performances, in terms of mass loss (~7% after 12 days), hydrogen release rate (~6 mL/cm2 after 12 days), electrochemical corrosion parameters and cytocompatibility, were obtained for the crystalline HA coating.
In Vitro Study on the Degradation Behavior of Different Antibiotic-Loaded Biomaterials for Orthopedic Applications
Local antibiotic delivery systems are increasingly used in orthopedic surgery to achieve optimal drug concentrations at the site of infection while minimizing systemic side effects. Among these systems, calcium sulfate-based resorbable cements and polymethyl methacrylate-based acrylic cements are commonly used. In this study, the structure, surface properties, and in vitro degradation behavior of CaSO4-based samples loaded with gentamicin, vancomycin, or a combination thereof were investigated and compared with those of a calcium sulfate control sample and polymethyl methacrylate-based acrylic cement. The characterization of the materials was performed using Fourier Transform Infrared Spectroscopy and Scanning Electron Microscopy coupled with Energy Dispersive X-ray Spectroscopy. Surface wettability was assessed using contact angle measurements, and immersion tests were used to evaluate water absorption and mass loss. The results showed that the introduction of antibiotics into CaSO4-based samples affected surface wettability, microstructure, and degradation profiles, particularly in samples containing gentamicin. A different behavior was observed in the case of acrylic cement, for which the mass loss is mainly attributed to the release of soluble components from the composition, such as residual monomer and antibiotics. Compared with acrylic cement, calcium sulfate-based samples, particularly those loaded with gentamicin, exhibited more hydrophilic surfaces and a microstructure that favors interaction with aqueous media, thereby leading to superior performance as local antibiotic delivery systems.
Mechanical and Computational Fluid Dynamic Models for Magnesium-Based Implants
Today, mechanical properties and fluid flow dynamic analysis are considered to be two of the most important steps in implant design for bone tissue engineering. The mechanical behavior is characterized by Young’s modulus, which must have a value close to that of the human bone, while from the fluid dynamics point of view, the implant permeability and wall shear stress are two parameters directly linked to cell growth, adhesion, and proliferation. In this study, we proposed two simple geometries with a three-dimensional pore network dedicated to a manufacturing route based on a titanium wire waving procedure used as an intermediary step for Mg-based implant fabrication. Implant deformation under different static loads, von Mises stresses, and safety factors were investigated using finite element analysis. The implant permeability was computed based on Darcy’s law following computational fluid dynamic simulations and, based on the pressure drop, was numerically estimated. It was concluded that both models exhibited a permeability close to the human trabecular bone and reduced wall shear stresses within the biological range. As a general finding, the proposed geometries could be useful in orthopedics for bone defect treatment based on numerical analyses because they mimic the trabecular bone properties.
Bioactive Hydroxyapatite–Collagen Composite Dressings for Wound Regeneration: Advances in Fabrication, Functionalization and Antimicrobial Strategies
Chronic and complex wounds, including diabetic foot ulcers, venous leg ulcers, burns and post-surgical defects, remain difficult to manage due to persistent inflammation, impaired angiogenesis, microbial colonization and insufficient extracellular matrix (ECM) remodeling. Conventional dressings provide protection, but they do not supply the necessary biochemical and structural signals for effective tissue repair. This review examines recent advances in hydroxyapatite–collagen (HAp–Col) composite dressings, which combine the architecture of collagen with the mechanical reinforcement and ionic bioactivity of hydroxyapatite. Analysis of the literature indicates that in situ and biomimetic mineralization, freeze-drying, electrospinning, hydrogel and film processing, and emerging 3D printing approaches enable precise control of pore structure, mineral dispersion, and degradation behavior. Antimicrobial functionalization remains critical: metallic ions and locally delivered antibiotics offer robust early antibacterial activity, while plant-derived essential oils (EOs) provide broad-spectrum antimicrobial, antioxidant and anti-inflammatory effects with reduced risk of resistance. Preclinical studies consistently report enhanced epithelialization, improved collagen deposition and reduced bacterial burden in HAp–Col systems; however, translation is limited by formulation variability, sterilization sensitivity and the lack of standardized clinical trials. Overall, HAp–Col composites represent a versatile framework for next-generation wound dressings that can address both regenerative and antimicrobial requirements.
Hydrogen Evolution Analyzed on Various Magnesium Alloys
The purpose of this study was to evaluate the biodegradability of some magnesium alloys, different both from the point of view of chemical composition and different system (Mg-Ca, Mg-Zn-Ag). Microstructural characteristics of experimental magnesium alloys were investigated using optical microscopy and scanning electron microscopy coupled with energy dispersive X-ray. The hydrogen evolution was analyzed using the method proposed by Song. The assessment was made through the evaluation of hydrogen released rate in simulated body fluid (SBF) as proposed by Kokubo and his colleagues, maintaining the temperature at 37 °C, for 240 hours. The studied samples showed different degradation rates depending on the chemical composition of magnesium based alloys and function of immersion time.