Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
1,614
result(s) for
"Force loading"
Sort by:
Automated Dielectrophoretic Tweezers-Based Force Spectroscopy System in a Microfluidic Device
by
Yoon, Young
,
Ko, Hyunchul
,
Lee, Sangyoup
in
Automation
,
dielectrophoresis
,
force loading rate
2017
We reported an automated dielectrophoretic (DEP) tweezers-based force spectroscopy system to examine intermolecular weak binding interactions, which consists of three components: (1) interdigitated electrodes and micro-sized polystyrene particles used as DEP tweezers and probes inside a microfluidic device, along with an arbitrary function generator connected to a high voltage amplifier; (2) microscopy hooked up to a high-speed charge coupled device (CCD) camera with an image acquisition device; and (3) a computer aid control system based on the LabVIEW program. Using this automated system, we verified the measurement reliability by measuring intermolecular weak binding interactions, such as hydrogen bonds and Van der Waals interactions. In addition, we also observed the linearity of the force loading rates, which is applied to the probes by the DEP tweezers, by varying the number of voltage increment steps and thus affecting the linearity of the force loading rates. This system provides a simple and low-cost platform to investigate intermolecular weak binding interactions.
Journal Article
Real-time biofeedback can increase and decrease vertical ground reaction force, knee flexion excursion, and knee extension moment during walking in individuals with anterior cruciate ligament reconstruction
by
Franz, Jason R.
,
Hackney, Anthony C.
,
Padua, Darin A.
in
Anterior cruciate ligament
,
Anterior Cruciate Ligament Reconstruction
,
Arthritis
2018
Individuals with anterior cruciate ligament reconstruction (ACLR) often exhibit a “stiffened knee strategy” or an excessively extended knee during gait, characterized by lesser knee flexion excursion and peak internal knee extension moment (KEM). The purpose of this study was to determine the effect of real-time biofeedback (RTBF) cuing an acute change in peak vertical ground reaction force (vGRF) during the first 50% of the stance phase of walking gait on: (1) root mean square error (RMSE) between actual vGRF and RTBF target vGRF; (2) perceived difficulty; and (3) knee biomechanics. Acquisition and short-term recall of these outcomes were evaluated. Thirty individuals with unilateral ACLR completed 4 separate walking sessions on a force-measuring treadmill that consisted of a control (no RTBF) and 3 experimental loading conditions using RTBF including: (1) 5% vGRF increase (high-loading), (2) 5% vGRF decrease (low-loading) and (3) symmetric vGRF between limbs. Bilateral biomechanical outcomes were analyzed during the first 50% of the stance phase, and included KEM, knee flexion excursion, peak vGRF, and instantaneous vGRF loading rate (vGRF-LR) for each loading condition. Peak vGRF significantly increased and decreased during high-loading and low-loading, respectively compared to control loading. Instantaneous vGRF-LR, peak KEM and knee flexion excursion significantly increased during the high-loading condition compared to low-loading. Perceived difficultly and RMSE were lower during the symmetrical loading condition compared to the low-loading condition. Cuing an increase in peak vGRF may be beneficial for increasing KEM, knee flexion excursion, peak vGRF, and vGRF-LR in individuals with ACLR. Clinical Trials Number: NCT03035994.
Journal Article
Study on the Control Method of Knee Joint Human–Exoskeleton Interactive System
by
Ding, Zhen
,
Tian, Bowen
,
Jiang, Feng
in
angle prediction
,
Biomechanical Phenomena
,
Controllers
2022
The advantages of exoskeletons based on the Bowden cable include being lightweight and flexible, thus being convenient in assisting humans. However, the performance of an exoskeleton is limited by the structure and human–exoskeleton interaction, which is analyzed from the established mathematical model of the human–exoskeleton system. In order to improve the auxiliary accuracy, corresponding control methods are proposed. The disturbance observer is designed to compensate for disturbances and parameter perturbations in the inner loop. The human–exoskeleton interaction feedforward model is integrated into the admittance control, which overcomes the limitation of the force loading caused by the friction of the Bowden cable and the change in stiffness of the human–exoskeleton interaction. Furthermore, an angle prediction method using the encoder as the signal source is designed to reduce the disturbance of the force loading caused by human motion. Finally, the effectiveness of the design method proposed in this paper is verified through experiments.
Journal Article
The glycocalyx affects the mechanotransductive perception of the topographical microenvironment
by
Podestà, Alessandro
,
Previdi, Anita
,
D’Urso, Mirko
in
Actin
,
Biomedical materials
,
Biotechnology
2022
The cell/microenvironment interface is the starting point of integrin-mediated mechanotransduction, but many details of mechanotransductive signal integration remain elusive due to the complexity of the involved (extra)cellular structures, such as the glycocalyx. We used nano-bio-interfaces reproducing the complex nanotopographical features of the extracellular matrix to analyse the glycocalyx impact on PC12 cell mechanosensing at the nanoscale (
e.g.
, by force spectroscopy with functionalised probes). Our data demonstrates that the glycocalyx configuration affects spatio-temporal nanotopography-sensitive mechanotransductive events at the cell/microenvironment interface. Opposing effects of major glycocalyx removal were observed, when comparing flat and specific nanotopographical conditions. The excessive retrograde actin flow speed and force loading are strongly reduced on certain nanotopographies upon strong reduction of the native glycocalyx, while on the flat substrate we observe the opposite trend. Our results highlight the importance of the glycocalyx configuration in a molecular clutch force loading-dependent cellular mechanism for mechanosensing of microenvironmental nanotopographical features.
Graphical Abstract
Journal Article
Biomechanical Characterization of Bionic Mechanical Harvesting of Tea Buds
2022
To date, mechanized picking of famous tea (bud, one bud one leaf) causes a lot of damage. Manual picking results in high-quality tea but the process is inefficient. Therefore, in order to improve the quality of mechanically harvested tea buds, the study of bionic picking is beneficial to reduce the damage rate of mechanical picking. In this paper, the manual flexible picking process is studied, and a bionic bladeless mechanical picking mechanics model is developed. The relationship between the mechanical properties and structural deformation of tea stalks is obtained by microstructural observation and mechanical experimental analysis and determination of the bud bionic picking mechanics flow by combined loading tests is carried out. The results show that the key factor for low damage in tea picking is the precise flexible force applied to different parts of the shoot tip during pinching, upward, and picking. The biological force of tea stalks is closely related to the stalk diameter and maturity of stalk tissue development. The larger the xylem of the tea stalk, the stronger its resistance to bending, stretching, and deformation. The stalks at the tender end of the tea are more resilient than the lower stalks and will not break under the action of large angle bending. Additionally, the stalks at the shoot tip have significantly lower pull-off force than the stalks at other places. By simulating the manual picking process, the mechanical picking mechanical parameters were determined to be a clamping pressure of 340 kPa, bending force of 0.134 N, and pull-off force of 5.1 N. These findings help the design of low-damage pickers for famous tea and provide a reference for low-damage bionic picking of tea.
Journal Article
Influence of Force Loading Methods on the Prediction Accuracy of Electromagnetic Vibration and Noise in Electric Motors with Different Pole/Slot Combinations
by
Deng, Wenzhe
,
Chen, Wei
,
Qian, Cheng
in
Acoustic noise
,
Electric motors
,
Electrical Engineering
2024
This study investigates the influence of three force loading methods on the prediction accuracy of electromagnetic vibration and noise in electric motors with different pole/slot combinations. The calculation approach of different electromagnetic force loading methods is firstly deduced and analyzed. Then, a multi-physics model for vibration and noise prediction is established and validated with a noise test. Finally, electric motors with three pole/slot combinations are selected, and the electromagnetic noise predicted by different force loading methods is compared. The results show that distributed force loading method of the electromagnetic force leads to a more accurate solution to the acoustic noise, even if the concentrated force considers the equivalent force couple produced by the translation of the nodal force action point. This study can provide guidance for the design of low-noise electric motors.
Journal Article
Mechanobiology Platform Realized Using Photomechanical Mxene Nanocomposites: Bilayer Photoactuator Design and In Vitro Mechanical Forces Stimulation
2022
Mechanotransduction is the process by which cells convert external forces and physical constraints into biochemical signals that control several aspects of cellular behavior. A number of approaches have been proposed to investigate the mechanisms of mechanotransduction; however, it remains a great challenge to develop a platform for dynamic multivariate mechanical stimulation of single cells and small colonies of cells. In this study, we combined polydimethylsiloxane (PDMS) and PDMS/Mxene nanoplatelets (MNPs) to construct a soft bilayer nanocomposite for extracellular mechanical stimulation. Fast backlash actuation of the bilayer as a result of near-infrared irradiation caused mechanical force stimulation of cells in a controllable manner. The excellent controllability of the light intensity and frequency allowed backlash bending acceleration and frequency to be manipulated. As gastric gland carcinoma cell line MKN-45 was the research subject, mechanical force loading conditions could trigger apoptosis of the cells in a stimulation duration time-dependent manner. Cell apoptotic rates were positively related to the duration time. In the case of 6 min mechanical force loading, apoptotic cell percentage rose to 34.46% from 5.5% of the control. This approach helps apply extracellular mechanical forces, even with predesigned loading cycles, and provides a solution to study cell mechanotransduction in complex force conditions. It is also a promising therapeutic technique for combining physical therapy and biomechanics.
Journal Article
Influence of Implant Number on Peri-Implant and Posterior Edentulous Area Strains in Mandibular Overdentures Retained by the New Ti–Zr (Roxolid®) Mini-Implants as Single-Units: In Vitro Study
2024
The new Ti–Zr (Roxolid®) mini-implants have not yet been fully researched. We analyzed peri-implant and posterior edentulous area microstrains during mandibular overdenture (OD) loading at different sites with different extents of forces when one-, two-, three-, or four- mini dental implants (MDIs) as single-units supported the respective ODs. The models were designed from cone beam computed tomography (CBCT) scans of an appropriate patient with narrow ridges. The mucosal thickness was 2 mm. Strain gauges were bonded on the vestibular and oral peri-implant sites, and in the distal edentulous area under the saddles. The loads were applied posteriorly bilaterally and unilaterally with 50, 100 and 150 N forces, and anteriorly with 50 and 100 N forces. Each loading was repeated 15 times. Statistical analysis included descriptive statistics, boxplots and the MANOVA. Higher forces induced higher peri-implant microstrains, as well as unilateral loadings, especially on the loaded side, in all models except the one-MDI model where anterior loads (100 N) elicited the highest peri-implant microstrain (1719.35 ± 76.0). The highest microstrains during unilateral posterior loading (right side) with 150 N force were registered from the right MDI in the two-MDI model (1836.64 ± 63.0). High microstrains were also recorded on the left side (1444.48 ± 54.6). By increasing the number of implants, peri-implant microstrains and those in the edentulous area decreased. In the three- and four-MDI models, higher microstrains were found in the posterior than in the anterior MDIs under posterior loadings. None of the recorded microstrains exceeded bone reparatory mechanisms, although precaution and additional research should be provided when only one or two MDIs support ODs.
Journal Article
Effects of Loading Forces, Loading Positions, and Splinting of Two, Three, or Four Ti-Zr (Roxolid®) Mini-Implants Supporting the Mandibular Overdentures on Peri-Implant and Posterior Edentulous Area Strains
2024
Clinical indications for the Ti-Zr alloy (Roxolid®) mini-implants (MDIs) in subjects with narrow ridges are still under review. The aim was to analyze peri-implant and posterior edentulous area strains dependent on the MDI number, splinting status, loading force, and loading position. Six models were digitally designed and printed. Two, three, or four Ti-Zr MDIs, splinted with a bar or unsplinted (single units), supported mandibular overdentures (ODs), loaded with 50–300 N forces unilaterally, bilaterally, and anteriorly. The artificial mucosa thickness was 2 mm. Strain gauges were bonded on the vestibular and oral peri-implant sides of each MDI, and on the posterior edentulous area under the ODs. Loadings were performed through the metal plate placed on ODs’ artificial teeth (15 times repeated). Arithmetic means with standard deviations and the significance of the differences (MANOVA, Sheffe post hoc) were calculated. Different MDI numbers, loading positions, forces, and splinting elicited different peri-implant microstrains. In the two-MDI models, 300 N force during unilateral loading elicited the highest microstrains (almost 3000 εμ on the loaded side), which can jeopardize bone reparation. On the opposite side, >2500 εμ was registered, which represents high strains. During bilateral loadings, microstrains hardly exceeded 2000 εμ, indicating that bilateral chewers or subjects having lower forces can benefit from the two Ti-Zr MDIs, irrespective of splinting. However, in subjects chewing unilaterally, and inducing higher forces (natural teeth antagonists), or bruxers, only two MDIs may not be sufficient to support the OD. By increasing implant numbers, peri-implant strains decrease in both splinted and single-unit MDI models, far beyond values that can interfere with bone reparation, indicating that splinting is not necessary. When the positions of the loading forces are closer to the implant, higher peri-implant strains are induced. Regarding the distal edentulous area, microstrains reached 2000 εμ only during unilateral loadings in the two-MDI models, and all other strains were lower, below 1500 εμ, confirming that implant-supported overdentures do not lead to edentulous ridge atrophy.
Journal Article
Mandibular Overdenture Supported by Two or Four Unsplinted or Two Splinted Ti-Zr Mini-Implants: In Vitro Study of Peri-Implant and Edentulous Area Strains
2024
Clinical indications for the newly released Ti-Zr (Roxolid®) alloy mini-implants (MDIs) aimed for overdenture (OD) retention in subjects with narrow alveolar ridges are not fully defined. The aim of this study was to analyze peri-implant and posterior edentulous area microstrains utilizing models of the mandible mimicking a “real” mouth situation with two (splinted with a bar or as single units) or four unsplinted Ti-Zr MDIs. The models were virtually designed from a cone beam computed tomography (CBCT) scan of a convenient patient and printed. The artificial mucosa was two millimeters thick. After MDI insertion, the strain gauges were bonded on the oral and vestibular peri-implant sites, and on distal edentulous areas under a denture. After attaching the ODs to MDIs, the ODs were loaded using a metal plate positioned on the first artificial molars (posterior loadings) bilaterally and unilaterally with 50, 100, and 150 N forces, respectively. During anterior loadings, the plate was positioned on the denture’s incisors and loaded with 50 and 100 N forces. Each loading was repeated 15 times. The means with standard deviations, and the significance of the differences (two- and three-factor MANOVA) were calculated. Variations in the MDI number, location, and splinting status elicited different microstrains. Higher loading forces elicited higher microstrains. Unilateral loadings elicited higher microstrains than bilateral and anterior loadings, especially on the loading side. Peri-implant microstrains were lower in the four-MDI single-unit model than in both two-MDI models (unsplinted and splinted). Posterior implants showed higher peri-implant microstrains than anterior in the four-MDI model. The splinting of the two-MDI did not have a significant effect on peri-implant microstrains but elicited lower microstrains in the posterior edentulous area. The strains did not exceed the bone reparatory mechanisms, although precaution and additional study should be addressed when two Ti-Zr MDIs support mandibular ODs.
Journal Article