Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Determination of methamphetamine, amphetamine and ecstasy by inside-needle adsorption trap based on molecularly imprinted polymer followed by GC-FID determination
by
Farajzadeh, Mir Ali
, Sorouraddin, Saeed Mohammad
, Baheri, Tahmineh
, Djozan, Djavanshir
in
Adsorption
/ Analysis
/ Analytical Chemistry
/ Characterization and Evaluation of Materials
/ Chemistry
/ Chemistry and Materials Science
/ Chromatographic methods and physical methods associated with chromatography
/ Exact sciences and technology
/ Gas chromatographic methods
/ Methamphetamine
/ Microengineering
/ Nanochemistry
/ Nanotechnology
/ Original Paper
/ Polymer industry
/ Steel, Stainless
2012
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Determination of methamphetamine, amphetamine and ecstasy by inside-needle adsorption trap based on molecularly imprinted polymer followed by GC-FID determination
by
Farajzadeh, Mir Ali
, Sorouraddin, Saeed Mohammad
, Baheri, Tahmineh
, Djozan, Djavanshir
in
Adsorption
/ Analysis
/ Analytical Chemistry
/ Characterization and Evaluation of Materials
/ Chemistry
/ Chemistry and Materials Science
/ Chromatographic methods and physical methods associated with chromatography
/ Exact sciences and technology
/ Gas chromatographic methods
/ Methamphetamine
/ Microengineering
/ Nanochemistry
/ Nanotechnology
/ Original Paper
/ Polymer industry
/ Steel, Stainless
2012
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Determination of methamphetamine, amphetamine and ecstasy by inside-needle adsorption trap based on molecularly imprinted polymer followed by GC-FID determination
by
Farajzadeh, Mir Ali
, Sorouraddin, Saeed Mohammad
, Baheri, Tahmineh
, Djozan, Djavanshir
in
Adsorption
/ Analysis
/ Analytical Chemistry
/ Characterization and Evaluation of Materials
/ Chemistry
/ Chemistry and Materials Science
/ Chromatographic methods and physical methods associated with chromatography
/ Exact sciences and technology
/ Gas chromatographic methods
/ Methamphetamine
/ Microengineering
/ Nanochemistry
/ Nanotechnology
/ Original Paper
/ Polymer industry
/ Steel, Stainless
2012
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Determination of methamphetamine, amphetamine and ecstasy by inside-needle adsorption trap based on molecularly imprinted polymer followed by GC-FID determination
Journal Article
Determination of methamphetamine, amphetamine and ecstasy by inside-needle adsorption trap based on molecularly imprinted polymer followed by GC-FID determination
2012
Request Book From Autostore
and Choose the Collection Method
Overview
We have developed a solvent-free and sensitive method for the identification and quantification of methamphetamine (MAMP), amphetamine (AMP) and ecstasy (MDMA) in human urine. It is based on the use of an inside-needle adsorption trap (INAT) and a molecularly imprinted polymer (MIP). The MAMP-MIP layer was coated on the internal surface of a hollow stainless steel needle, which was oxidized and silylated. It was used as the extraction needle. A model solution containing the drugs was slowly passed through the extraction needle. After adsorption of the analytes, the needle was directly transferred to the injector of a gas chromatograph, where the analytes were thermally desorbed, separated by GC, and detected with a flame ionization detector. The method does not require an extraction solvent, is fast and simple. The linear range of the calibration graphs are rather wide, and the limit of detection and the limit of quantification (LOQ) for MAMP are 12 and 40 ng mL
−1
, respectively. The relative standard deviations (RSD%) for six repeated experiments (at 500 ng mL
−1
of MAMP) is 4.9 %. The relative recoveries obtained for MAMP in spiked human urine samples are in the range of 81–93 %.
Graphical Abstract Figure
Typical chromatograms corresponding to the extraction of MAMP, AMP and MDMA in the optimum condition from human urine sample. Lower chromatogram (I) belong to non-spiked samples after extraction using MAMP-MIP coated needle and the other chromatograms, (II) and (III), are related to spiked samples with MAMP, AMP and MDMA (each 0.5 μg mL
−1
) and extraction using the NIP-coated needle and MAMP-MIP coated needle, respectively.
Publisher
Springer Vienna,Springer
This website uses cookies to ensure you get the best experience on our website.