MbrlCatalogueTitleDetail

Do you wish to reserve the book?
HAI-Proactive: Development of an Automated Surveillance System for Healthcare-Associated Infections in Sweden
HAI-Proactive: Development of an Automated Surveillance System for Healthcare-Associated Infections in Sweden
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
HAI-Proactive: Development of an Automated Surveillance System for Healthcare-Associated Infections in Sweden
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
HAI-Proactive: Development of an Automated Surveillance System for Healthcare-Associated Infections in Sweden
HAI-Proactive: Development of an Automated Surveillance System for Healthcare-Associated Infections in Sweden

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
HAI-Proactive: Development of an Automated Surveillance System for Healthcare-Associated Infections in Sweden
HAI-Proactive: Development of an Automated Surveillance System for Healthcare-Associated Infections in Sweden
Journal Article

HAI-Proactive: Development of an Automated Surveillance System for Healthcare-Associated Infections in Sweden

2020
Request Book From Autostore and Choose the Collection Method
Overview
Background: Healthcare-associated infection (HAI) surveillance is essential for most infection prevention programs and continuous epidemiological data can be used to inform healthcare personal, allocate resources, and evaluate interventions to prevent HAIs. Many HAI surveillance systems today are based on time-consuming and resource-intensive manual reviews of patient records. The objective of HAI-proactive, a Swedish triple-helix innovation project, is to develop and implement a fully automated HAI surveillance system based on electronic health record data. Furthermore, the project aims to develop machine-learning–based screening algorithms for early prediction of HAI at the individual patient level. Methods: The project is performed with support from Sweden’s Innovation Agency in collaboration among academic, health, and industry partners. Development of rule-based and machine-learning algorithms is performed within a research database, which consists of all electronic health record data from patients admitted to the Karolinska University Hospital. Natural language processing is used for processing free-text medical notes. To validate algorithm performance, manual annotation was performed based on international HAI definitions from the European Center for Disease Prevention and Control, Centers for Disease Control and Prevention, and Sepsis-3 criteria. Currently, the project is building a platform for real-time data access to implement the algorithms within Region Stockholm. Results: The project has developed a rule-based surveillance algorithm for sepsis that continuously monitors patients admitted to the hospital, with a sensitivity of 0.89 (95% CI, 0.85–0.93), a specificity of 0.99 (0.98–0.99), a positive predictive value of 0.88 (0.83–0.93), and a negative predictive value of 0.99 (0.98–0.99). The healthcare-associated urinary tract infection surveillance algorithm, which is based on free-text analysis and negations to define symptoms, had a sensitivity of 0.73 (0.66–0.80) and a positive predictive value of 0.68 (0.61–0.75). The sensitivity and positive predictive value of an algorithm based on significant bacterial growth in urine culture only was 0.99 (0.97–1.00) and 0.39 (0.34–0.44), respectively. The surveillance system detected differences in incidences between hospital wards and over time. Development of surveillance algorithms for pneumonia, catheter-related infections and Clostridioides difficile infections, as well as machine-learning–based models for early prediction, is ongoing. We intend to present results from all algorithms. Conclusions: With access to electronic health record data, we have shown that it is feasible to develop a fully automated HAI surveillance system based on algorithms using both structured data and free text for the main healthcare-associated infections. Funding: Sweden’s Innovation Agency and Stockholm County Council Disclosures: None