MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Automatic alignment system device of micro–nanofluid control chip and its application
Automatic alignment system device of micro–nanofluid control chip and its application
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Automatic alignment system device of micro–nanofluid control chip and its application
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Automatic alignment system device of micro–nanofluid control chip and its application
Automatic alignment system device of micro–nanofluid control chip and its application

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Automatic alignment system device of micro–nanofluid control chip and its application
Automatic alignment system device of micro–nanofluid control chip and its application
Journal Article

Automatic alignment system device of micro–nanofluid control chip and its application

2022
Request Book From Autostore and Choose the Collection Method
Overview
Purpose The purpose of this study is to provide a micro-nano chip automatic alignment system. Used for micron and nanometer channel alignment of microfluidic chip. Design/methodology/approach In this paper, combined with the reconstructed micro–nanoscale Hough transform theory, a “clamp–adsorb–rotate” chip alignment method is proposed. The designed alignment system includes a microscopic identification device, a clamping device and a suction device. After assembly, the straightness of the linear slide rail in the horizontal and vertical directions was tested, respectively. The results show that in the horizontal and vertical directions, the linearity error of the linear slide is +0.29 and 0.30 µm, respectively, which meets the requirement of chip alignment accuracy of 15 µm. In the direction of rotation, the angular error between the microchannel and the nanochannel is ±0.5°. In addition, an alignment flow experiment of the chip is designed. The results demonstrate that the closer the angle between the microchannel and the nanochannel is to 90°, the fluid fills the entire channel. Compared with the conventional method, the method and the assembly system realize fully automatic double-layer chip alignment. Findings A mechanical device designed by Hough transform theory can realize microfluidic chip alignment at nanometer and micron level. Originality/value The automatic alignment device adopts Hough transform principle and can be used for microfluidic chip alignment.