Maximizing precision and accuracy of the doubly labeled water method via optimal sampling protocol, calculation choices, and incorporation of 17O measurements
by
Swibas Tracy
, Speakman, John R
, Creasy, Seth A
, Kohrt, Wendy M
, Catenacci, Vicki A
, Berman Elena S F
, Melanson, Edward L
in
Accuracy
/ Carbon dioxide
/ Dilution
/ Energy expenditure
/ Fluctuations
/ Isotope ratios
/ Mathematical analysis
/ New technology
/ Optimization
/ Sampling
/ Spectroscopy
2020
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Maximizing precision and accuracy of the doubly labeled water method via optimal sampling protocol, calculation choices, and incorporation of 17O measurements
by
Swibas Tracy
, Speakman, John R
, Creasy, Seth A
, Kohrt, Wendy M
, Catenacci, Vicki A
, Berman Elena S F
, Melanson, Edward L
in
Accuracy
/ Carbon dioxide
/ Dilution
/ Energy expenditure
/ Fluctuations
/ Isotope ratios
/ Mathematical analysis
/ New technology
/ Optimization
/ Sampling
/ Spectroscopy
2020
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Maximizing precision and accuracy of the doubly labeled water method via optimal sampling protocol, calculation choices, and incorporation of 17O measurements
by
Swibas Tracy
, Speakman, John R
, Creasy, Seth A
, Kohrt, Wendy M
, Catenacci, Vicki A
, Berman Elena S F
, Melanson, Edward L
in
Accuracy
/ Carbon dioxide
/ Dilution
/ Energy expenditure
/ Fluctuations
/ Isotope ratios
/ Mathematical analysis
/ New technology
/ Optimization
/ Sampling
/ Spectroscopy
2020
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Maximizing precision and accuracy of the doubly labeled water method via optimal sampling protocol, calculation choices, and incorporation of 17O measurements
Journal Article
Maximizing precision and accuracy of the doubly labeled water method via optimal sampling protocol, calculation choices, and incorporation of 17O measurements
2020
Request Book From Autostore
and Choose the Collection Method
Overview
Background/ObjectivesThe doubly labeled water (DLW) method is the gold standard methodology for determination of free-living, total daily energy expenditure (TEE). However, there is no single accepted approach for either the sampling protocols (daily vs. two-point, in which samples are collected after dosing and at the end of the measurement period) or the calculations used in the determination of the rate of carbon dioxide production (rCO2) and TEE. Moreover, fluctuations in natural background abundances introduce error in the calculation of rCO2 and TEE. The advent of new technologies makes feasible the possibility of including additional isotope measures (17O) to account for background variation, which may improve accuracy.Subjects/MethodsSixteen subjects were studied for 7 consecutive days in a whole-room indirect calorimeter (IC) with concurrent measurement of TEE by DLW. Daily urine samples were obtained and isotope ratios were determined using off-axis integrated cavity output spectroscopy (OA-ICOS).ResultsWe determined the best combination of approaches for estimating dilution spaces and elimination rates and calculated average daily volume of carbon dioxide production (VCO2) using six different published equations. Using this best combination, multi-point fitting of isotope elimination rates using the daily urine samples substantially improved the average precision (4.5% vs. 6.0%) and accuracy (−0.5% vs. −3.0%) compared with the two-point method. This improvement may partly reflect the less variable day-to-day chamber measurements of energy expenditure. Utilizing 17O measurements to correct for errors due to background isotope fluctuations provided additional but minor improvements in precision (4.2% vs. 4.5%) and accuracy (0.2% vs. 0.5%).ConclusionsThis work shows that optimizing sampling and calculation protocols can improve the accuracy and precision of DLW measurements.
Publisher
Nature Publishing Group
Subject
This website uses cookies to ensure you get the best experience on our website.