MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Parametric study and optimization of the precooled Linde–Hampson (PCLH) cycle for six different gases based on energy and exergy analysis
Parametric study and optimization of the precooled Linde–Hampson (PCLH) cycle for six different gases based on energy and exergy analysis
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Parametric study and optimization of the precooled Linde–Hampson (PCLH) cycle for six different gases based on energy and exergy analysis
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Parametric study and optimization of the precooled Linde–Hampson (PCLH) cycle for six different gases based on energy and exergy analysis
Parametric study and optimization of the precooled Linde–Hampson (PCLH) cycle for six different gases based on energy and exergy analysis

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Parametric study and optimization of the precooled Linde–Hampson (PCLH) cycle for six different gases based on energy and exergy analysis
Parametric study and optimization of the precooled Linde–Hampson (PCLH) cycle for six different gases based on energy and exergy analysis
Journal Article

Parametric study and optimization of the precooled Linde–Hampson (PCLH) cycle for six different gases based on energy and exergy analysis

2023
Request Book From Autostore and Choose the Collection Method
Overview
Diverse methods have been proposed for liquefying gases due to their need in different industries. This study examined the precooled Linde–Hampson cycle for liquefying six gases. First, the proposed system is analyzed from a thermodynamic perspective. Then, the effects of pressure ratio on performance parameters such as system required work, heat exchanger-specific heat capacity, number of transfer units, the liquefied gas mass ratio, Coefficient of Performance (COP), and exergy efficiency are examined. The results show that methane at a pressure ratio of 40 has the highest COP (1.606), while argon at a pressure ratio of 220 has the highest exergy efficiency (31.51%). Exergy analysis indicates that the Joule–Thomson valve destroys the most exergy, followed by heat exchanger-3 and compressor-1. Finally, the TOPSIS technique is used as a multi-objective optimization method to optimize the compressor-1 pressure ratio based on two objective functions, COP and exergy efficiency. The results show that in optimal conditions, COP and exergy efficiency are respectively 0.99 and 20.6% for air, 0.93 and 28.35% for argon, 0.97 and 20% for nitrogen, 1.46 and 14.76% for methane, 1.05 and 22.87% for fluorine, and 1.18 and 20.08% for oxygen.