Mechanical Cryocooler Noise Observed in the Ground Testing of the Resolve X-ray Microcalorimeter Onboard XRISM
by
Kelley, R. L.
, Imamura, R.
, Tsujimoto, M.
, Awaki, H.
, Kilbourne, C. A.
, Yamada, S.
, Porter, F. S.
, Takei, Y.
in
Accelerometers
/ Ambient temperature
/ Characterization and Evaluation of Materials
/ Condensed Matter Physics
/ Coolers
/ Cooling
/ Cryogenic cooling
/ Energy resolution
/ Ground tests
/ Harmonics
/ Low temperature
/ Magnetic Materials
/ Magnetism
/ Noise spectra
/ Operating temperature
/ Physics
/ Physics and Astronomy
/ Sensors
/ Spectrum analysis
/ X ray detectors
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Mechanical Cryocooler Noise Observed in the Ground Testing of the Resolve X-ray Microcalorimeter Onboard XRISM
by
Kelley, R. L.
, Imamura, R.
, Tsujimoto, M.
, Awaki, H.
, Kilbourne, C. A.
, Yamada, S.
, Porter, F. S.
, Takei, Y.
in
Accelerometers
/ Ambient temperature
/ Characterization and Evaluation of Materials
/ Condensed Matter Physics
/ Coolers
/ Cooling
/ Cryogenic cooling
/ Energy resolution
/ Ground tests
/ Harmonics
/ Low temperature
/ Magnetic Materials
/ Magnetism
/ Noise spectra
/ Operating temperature
/ Physics
/ Physics and Astronomy
/ Sensors
/ Spectrum analysis
/ X ray detectors
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Mechanical Cryocooler Noise Observed in the Ground Testing of the Resolve X-ray Microcalorimeter Onboard XRISM
by
Kelley, R. L.
, Imamura, R.
, Tsujimoto, M.
, Awaki, H.
, Kilbourne, C. A.
, Yamada, S.
, Porter, F. S.
, Takei, Y.
in
Accelerometers
/ Ambient temperature
/ Characterization and Evaluation of Materials
/ Condensed Matter Physics
/ Coolers
/ Cooling
/ Cryogenic cooling
/ Energy resolution
/ Ground tests
/ Harmonics
/ Low temperature
/ Magnetic Materials
/ Magnetism
/ Noise spectra
/ Operating temperature
/ Physics
/ Physics and Astronomy
/ Sensors
/ Spectrum analysis
/ X ray detectors
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Mechanical Cryocooler Noise Observed in the Ground Testing of the Resolve X-ray Microcalorimeter Onboard XRISM
Journal Article
Mechanical Cryocooler Noise Observed in the Ground Testing of the Resolve X-ray Microcalorimeter Onboard XRISM
2023
Request Book From Autostore
and Choose the Collection Method
Overview
Low-temperature detectors often use mechanical coolers as part of the cooling chain in order to reach sub-Kelvin operating temperatures. The microphonic noise caused by the mechanical coolers is a general and inherent issue for these detectors. We have observed this effect in the ground test data obtained with the
Resolve
instrument to be flown on the XRISM satellite.
Resolve
is a cryogenic X-ray microcalorimeter spectrometer with a required energy resolution of 7 eV at 6 keV. Five mechanical coolers are used to cool from ambient temperature to
∼
4 K: four two-stage Stirling coolers (STC) driven nominally at 15 Hz and a Joule–Thomson cooler (JTC) driven nominally at 52 Hz. In 2019, we operated the flight-model instrument for two weeks, in which we also obtained accelerometer data inside the cryostat at a low-temperature stage (He tank). X-ray detector and accelerometer data were obtained continuously while changing the JTC drive frequency, which produced a unique data set for investigating how the vibration from the cryocoolers propagates to the detector. In the detector noise spectra, we observed harmonics of both STCs and JTC. More interestingly, we also observed the low (
<
20
Hz) frequency beat between the 4th JTC and 14th STC harmonics and the 7th JTC and the 23–24th STC harmonics. We present here a description and interpretation of these measurements.