Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Percutaneous thoraco-lumbar-sacral pedicle screw placement accuracy results from a multi-center, prospective clinical study using a skin marker-based optical navigation system
by
Sedaghat, Sam
, Chianca, Vito
, Klüter, Tim
, Distefano, Daniela
, Seekamp, Andreas
, Scarone, Pietro
, Lampe, Finn
, Jenniskens, Inge
, Weuster, Matthias
, Nelson, Melissa
, Chatterjea, Anindita
, Lippross, Sebastian
, Presilla, Stefano
in
Accuracy
/ Navigation systems
/ Patients
/ Radiation
/ Radiation measurement
/ Sacrum
/ Skin
/ Thorax
2022
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Percutaneous thoraco-lumbar-sacral pedicle screw placement accuracy results from a multi-center, prospective clinical study using a skin marker-based optical navigation system
by
Sedaghat, Sam
, Chianca, Vito
, Klüter, Tim
, Distefano, Daniela
, Seekamp, Andreas
, Scarone, Pietro
, Lampe, Finn
, Jenniskens, Inge
, Weuster, Matthias
, Nelson, Melissa
, Chatterjea, Anindita
, Lippross, Sebastian
, Presilla, Stefano
in
Accuracy
/ Navigation systems
/ Patients
/ Radiation
/ Radiation measurement
/ Sacrum
/ Skin
/ Thorax
2022
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Percutaneous thoraco-lumbar-sacral pedicle screw placement accuracy results from a multi-center, prospective clinical study using a skin marker-based optical navigation system
by
Sedaghat, Sam
, Chianca, Vito
, Klüter, Tim
, Distefano, Daniela
, Seekamp, Andreas
, Scarone, Pietro
, Lampe, Finn
, Jenniskens, Inge
, Weuster, Matthias
, Nelson, Melissa
, Chatterjea, Anindita
, Lippross, Sebastian
, Presilla, Stefano
in
Accuracy
/ Navigation systems
/ Patients
/ Radiation
/ Radiation measurement
/ Sacrum
/ Skin
/ Thorax
2022
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Percutaneous thoraco-lumbar-sacral pedicle screw placement accuracy results from a multi-center, prospective clinical study using a skin marker-based optical navigation system
Journal Article
Percutaneous thoraco-lumbar-sacral pedicle screw placement accuracy results from a multi-center, prospective clinical study using a skin marker-based optical navigation system
2022
Request Book From Autostore
and Choose the Collection Method
Overview
Study designProspective multi-center study.ObjectiveThe study aimed to evaluate the accuracy of pedicle screw placement using a skin marker-based optical surgical navigation system for minimal invasive thoraco-lumbar-sacral pedicle screw placement.MethodsThe study was performed in a hybrid Operating Room with a video camera-based navigation system integrated in the imaging hardware. The patient was tracked with non-invasive skin markers while the instrument tracking was via an on-shaft optical marker pattern. The screw placement accuracy assessment was performed by three independent reviewers, using the Gertzbein grading. The screw placement time as well as the staff and patient radiation doses was also measured.ResultsIn total, 211 screws in 39 patients were analyzed for screw placement accuracy. Of these 32.7% were in the thoracic region, 59.7% were in the lumbar region, and 7.6% were in the sacral region. An overall accuracy of 98.1% was achieved. No screws were deemed severely misplaced (Gertzbein grading 3). The average time for screw placement was 6 min and 25 secs (± 3 min 33 secs). The average operator radiation dose per subject was 40.3 µSv. The mean patient effective dose (ED) was 11.94 mSv.ConclusionSkin marker-based ON can be used to achieve very accurate thoracolumbarsacral pedicle screw placements.