Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Lung ultrasound-guided best positive end-expiratory pressure in neonatal anesthesia: a proposed randomized, controlled study
by
Buonsenso, Danilo
, Camporesi, Anna
, Gentile, Andrea
, Pelizzo, Gloria
, Paladini, Giuseppe
, Pierucci, Ugo Maria
in
Clinical trials
/ Hemodynamics
/ Hypoxemia
/ Medicine
/ Medicine & Public Health
/ Pediatric Surgery
/ Pediatrics
/ Respiratory system
/ Study Protocol
/ Ultrasonic imaging
/ Ventilators
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Lung ultrasound-guided best positive end-expiratory pressure in neonatal anesthesia: a proposed randomized, controlled study
by
Buonsenso, Danilo
, Camporesi, Anna
, Gentile, Andrea
, Pelizzo, Gloria
, Paladini, Giuseppe
, Pierucci, Ugo Maria
in
Clinical trials
/ Hemodynamics
/ Hypoxemia
/ Medicine
/ Medicine & Public Health
/ Pediatric Surgery
/ Pediatrics
/ Respiratory system
/ Study Protocol
/ Ultrasonic imaging
/ Ventilators
2024
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Lung ultrasound-guided best positive end-expiratory pressure in neonatal anesthesia: a proposed randomized, controlled study
by
Buonsenso, Danilo
, Camporesi, Anna
, Gentile, Andrea
, Pelizzo, Gloria
, Paladini, Giuseppe
, Pierucci, Ugo Maria
in
Clinical trials
/ Hemodynamics
/ Hypoxemia
/ Medicine
/ Medicine & Public Health
/ Pediatric Surgery
/ Pediatrics
/ Respiratory system
/ Study Protocol
/ Ultrasonic imaging
/ Ventilators
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Lung ultrasound-guided best positive end-expiratory pressure in neonatal anesthesia: a proposed randomized, controlled study
Journal Article
Lung ultrasound-guided best positive end-expiratory pressure in neonatal anesthesia: a proposed randomized, controlled study
2024
Request Book From Autostore
and Choose the Collection Method
Overview
Background
Atelectasis is a common complication in neonatal anesthesia. Lung ultrasound (LUS) can be used intraoperatively to evaluate and recognize atelectatic lung areas. Hypotheses for the study are: (1) The use of LUS to guide choice of
best positive end-expiratory pressure
(
PEEP
) can lead to reduction of FiO
2
to achieve same saturations of oxygen (SpO
2
). (2) In a less de-recruited lung, there will be less postoperative pulmonary complications. (3) Static respiratory system compliance could be different. (4) Hemodynamic parameters and amount of fluids infused or need for vasopressors intraoperatively could be different.
Methods
We propose a randomized controlled trial that compares standard PEEP settings with LUS-guided PEEP choice in patients under 2 months of age undergoing general anesthesia.
Results
The primary aim is to determine whether LUS-guided PEEP choice in neonatal anesthesia, compared to standard PEEP choice, can lead to reduction of FiO
2
applied to the ventilatory setting in order to maintain same SpO
2
s. Secondary aims are to determine whether patients treated with LUS-guided PEEP will develop less postoperative pulmonary complications, will have a significant difference in hemodynamic parameters and amount of fluids or vasopressors infused, and in static respiratory system compliance.
Conclusions
We expect a significant reduction of FiO
2
in LUS-guided ventilation.
Impact
Lung atelectasis is extremely common in neonatal anesthesia, because of the physiology of the neonatal lung and chest wall and leads to hypoxemia, being a lung area with a perfusion/ventilation mismatch.
Raising inspired fraction of oxygen can overcome temporarily hypoxemia but oxygen is a toxic compound for newborns. Lung ultrasound (LUS) can detect atelectasis at bedside and be used to optimize ventilator settings including choice of positive end-expiratory pressure (PEEP).
This randomized controlled trial (RCT) aims at demonstrating that LUS-guided choice of best PEEP during neonatal anesthesia can lead to reduction of inspired fractions of oxygen to keep same peripheral saturations SpO
2
.
Publisher
Nature Publishing Group US,Nature Publishing Group
This website uses cookies to ensure you get the best experience on our website.