Monitoring the Dilution of Buffer Solutions with Different pH Values above and below Physiological pH in Very Small Volumes
by
Blaschke, Daniel
, Burgold-Voigt, Sindy
, Bhat, Vinayak J.
, Vegesna, Sahitya V.
, Ehricht, Ralf
, Schmidt, Heidemarie
, Müller, Elke
in
Automation
/ Biosensing Techniques - methods
/ Buffers
/ Cellulose acetate
/ Contact angle
/ dilution
/ Electric Impedance
/ Electrodes
/ equivalent circuit modeling
/ Hydrogen-Ion Concentration
/ impedance measurement
/ impedance spectroscopy
/ Physiology
/ PolCarr® impedance chip
/ Sensors
/ Silicon - chemistry
/ Silicon wafers
/ Solutions - chemistry
/ Water - chemistry
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Monitoring the Dilution of Buffer Solutions with Different pH Values above and below Physiological pH in Very Small Volumes
by
Blaschke, Daniel
, Burgold-Voigt, Sindy
, Bhat, Vinayak J.
, Vegesna, Sahitya V.
, Ehricht, Ralf
, Schmidt, Heidemarie
, Müller, Elke
in
Automation
/ Biosensing Techniques - methods
/ Buffers
/ Cellulose acetate
/ Contact angle
/ dilution
/ Electric Impedance
/ Electrodes
/ equivalent circuit modeling
/ Hydrogen-Ion Concentration
/ impedance measurement
/ impedance spectroscopy
/ Physiology
/ PolCarr® impedance chip
/ Sensors
/ Silicon - chemistry
/ Silicon wafers
/ Solutions - chemistry
/ Water - chemistry
2024
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Monitoring the Dilution of Buffer Solutions with Different pH Values above and below Physiological pH in Very Small Volumes
by
Blaschke, Daniel
, Burgold-Voigt, Sindy
, Bhat, Vinayak J.
, Vegesna, Sahitya V.
, Ehricht, Ralf
, Schmidt, Heidemarie
, Müller, Elke
in
Automation
/ Biosensing Techniques - methods
/ Buffers
/ Cellulose acetate
/ Contact angle
/ dilution
/ Electric Impedance
/ Electrodes
/ equivalent circuit modeling
/ Hydrogen-Ion Concentration
/ impedance measurement
/ impedance spectroscopy
/ Physiology
/ PolCarr® impedance chip
/ Sensors
/ Silicon - chemistry
/ Silicon wafers
/ Solutions - chemistry
/ Water - chemistry
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Monitoring the Dilution of Buffer Solutions with Different pH Values above and below Physiological pH in Very Small Volumes
Journal Article
Monitoring the Dilution of Buffer Solutions with Different pH Values above and below Physiological pH in Very Small Volumes
2024
Request Book From Autostore
and Choose the Collection Method
Overview
The accurate determination of the post-dilution concentration of biological buffers is essential for retaining the necessary properties and effectiveness of the buffer to maintain stable cellular environments and optimal conditions for biochemical reactions. In this work, we introduce a silicon-based impedance chip, which offers a rapid and reagent-free approach for monitoring the buffer concentrations after dilution with deionized (DI) water. The impedance of the impedance chip is measured, and the impedance data are modeled using a multiparameter equivalent circuit model. We investigated six aqueous biological buffers with pH values above and below the physiological pH for most tissues (pH ~ 7.2–7.4) following dilution with DI water by factors of 2.0, 10.0, 20.0, 100.0, and 200.0. The impedance measurement is then performed for the frequency spectrum of 40 Hz to 1 MHz. From the interpretation of the impedance measurement using the multiparameter equivalent circuit model, we report a buffer-sensitive equivalent circuit parameter RAu/Si of the silicon-based impedance chip showing a linear trend on a logarithmic scale with the buffer concentration change after dilution. The parameter RAu/Si is independent of the buffer pH and the added volume. The results demonstrate the efficacy of the silicon-based impedance chip as a versatile tool for precise post-dilution concentration determination of diverse biologically relevant buffers. The presented impedance chip offers rapid, accurate, and reliable monitoring, making it highly suitable for integration into automated liquid-handling systems to enhance the efficiency and precision of biological and chemical processes.