Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Electrochemical Corrosion Behavior of Ti-N-O Modified Layer on the TC4 Titanium Alloy Prepared by Hollow Cathodic Plasma Source Oxynitriding
by
Yi, Xuening
, Wang, Chengxu
, Shao, Minghao
, Zhou, Zelong
, Xie, Bing
, Wang, Mingjia
, Fang, Dazhen
, Wang, Mufan
, Li, Yang
, He, Yongyong
, Zhang, Zhehao
, Yan, Jiwen
in
artificial saliva
/ Biocompatibility
/ Chemical vapor deposition
/ Corrosion and anti-corrosives
/ Corrosion currents
/ Corrosion resistance
/ Damage prevention
/ EIS
/ Electrochemical corrosion
/ electrochemical testing
/ Electrodes
/ Fluorides
/ Hollow cathodes
/ Implant dentures
/ Mechanical properties
/ Microhardness
/ Nitrogen
/ Oxynitriding
/ Plasma
/ Plasma physics
/ Software
/ Specialty metals industry
/ Spectrum analysis
/ Surface hardness
/ Surgical implants
/ TC4 alloy
/ Titanium
/ Titanium alloys
/ Titanium base alloys
/ Titanium dioxide
/ XPS
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Electrochemical Corrosion Behavior of Ti-N-O Modified Layer on the TC4 Titanium Alloy Prepared by Hollow Cathodic Plasma Source Oxynitriding
by
Yi, Xuening
, Wang, Chengxu
, Shao, Minghao
, Zhou, Zelong
, Xie, Bing
, Wang, Mingjia
, Fang, Dazhen
, Wang, Mufan
, Li, Yang
, He, Yongyong
, Zhang, Zhehao
, Yan, Jiwen
in
artificial saliva
/ Biocompatibility
/ Chemical vapor deposition
/ Corrosion and anti-corrosives
/ Corrosion currents
/ Corrosion resistance
/ Damage prevention
/ EIS
/ Electrochemical corrosion
/ electrochemical testing
/ Electrodes
/ Fluorides
/ Hollow cathodes
/ Implant dentures
/ Mechanical properties
/ Microhardness
/ Nitrogen
/ Oxynitriding
/ Plasma
/ Plasma physics
/ Software
/ Specialty metals industry
/ Spectrum analysis
/ Surface hardness
/ Surgical implants
/ TC4 alloy
/ Titanium
/ Titanium alloys
/ Titanium base alloys
/ Titanium dioxide
/ XPS
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Electrochemical Corrosion Behavior of Ti-N-O Modified Layer on the TC4 Titanium Alloy Prepared by Hollow Cathodic Plasma Source Oxynitriding
by
Yi, Xuening
, Wang, Chengxu
, Shao, Minghao
, Zhou, Zelong
, Xie, Bing
, Wang, Mingjia
, Fang, Dazhen
, Wang, Mufan
, Li, Yang
, He, Yongyong
, Zhang, Zhehao
, Yan, Jiwen
in
artificial saliva
/ Biocompatibility
/ Chemical vapor deposition
/ Corrosion and anti-corrosives
/ Corrosion currents
/ Corrosion resistance
/ Damage prevention
/ EIS
/ Electrochemical corrosion
/ electrochemical testing
/ Electrodes
/ Fluorides
/ Hollow cathodes
/ Implant dentures
/ Mechanical properties
/ Microhardness
/ Nitrogen
/ Oxynitriding
/ Plasma
/ Plasma physics
/ Software
/ Specialty metals industry
/ Spectrum analysis
/ Surface hardness
/ Surgical implants
/ TC4 alloy
/ Titanium
/ Titanium alloys
/ Titanium base alloys
/ Titanium dioxide
/ XPS
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Electrochemical Corrosion Behavior of Ti-N-O Modified Layer on the TC4 Titanium Alloy Prepared by Hollow Cathodic Plasma Source Oxynitriding
Journal Article
Electrochemical Corrosion Behavior of Ti-N-O Modified Layer on the TC4 Titanium Alloy Prepared by Hollow Cathodic Plasma Source Oxynitriding
2023
Request Book From Autostore
and Choose the Collection Method
Overview
TC4 alloy is widely used in dental implantation due to its excellent biocompatibility and low density. However, it is necessary to further improve the corrosion resistance and surface hardness of the titanium alloy to prevent surface damage that could result in the release of metal ions into the oral cavity, potentially affecting oral health. In this study, Ti-N-O layers were fabricated on the surface of TC4 alloy using a two-step hollow cathode plasma source oxynitriding technique. This resulted in the formation of TiN, Ti2N, TiO2, and nitrogen-stabilized α(N)-Ti phases on the TC4 alloy, forming a Ti-N-O modified layer. The microhardness of the samples treated with plasma oxynitriding (PNO) was found to be 300–400% higher than that of untreated (UN) samples. The experimental conditions were set at 520 °C, and the corrosion current density of the PNO sample was measured to be 7.65 × 10−8 A/cm2, which is two orders of magnitude lower than that of the UN sample. This indicates that the PNO-treated TC4 alloy exhibited significantly improved corrosion resistance in the artificial saliva solutions.
This website uses cookies to ensure you get the best experience on our website.