Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial
by
Walther, Thomas
, Conzelmann, Lars
, Heg, Dik
, Lanz, Jonas
, Windecker, Stephan
, Jüni, Peter
, Kerber, Sebastian
, Husser, Oliver
, Linke, Axel
, Stortecky, Stefan
, Thilo, Christian
, Prendergast, Bernard
, Kim, Won-Keun
, Joner, Michael
, Thiele, Holger
, Pilgrim, Thomas
, Hilker, Michael
, Möllmann, Helge
, Burgdorf, Christof
, Redwood, Simon
, Schymik, Gerhard
, Conradi, Lenard
in
Aged
/ Aged, 80 and over
/ Aortic stenosis
/ Aortic valve
/ Aortic Valve Stenosis - epidemiology
/ Aortic Valve Stenosis - mortality
/ Aortic Valve Stenosis - surgery
/ Balloon treatment
/ Bioprosthesis - adverse effects
/ Bleeding
/ Catheters
/ Cause of Death - trends
/ Clinical outcomes
/ Clinical trials
/ Confidence limits
/ Congestive heart failure
/ Coronary artery
/ Electrocardiography
/ Female
/ Germany - epidemiology
/ Heart attacks
/ Heart Valve Prosthesis - adverse effects
/ Heart valves
/ Humans
/ Kidneys
/ Male
/ Mortality risk
/ Netherlands - epidemiology
/ Patients
/ Postoperative Complications - epidemiology
/ Prostheses
/ Prosthesis Design
/ Randomization
/ Regurgitation
/ Risk
/ Safety
/ Secondary analysis
/ Severity of Illness Index
/ Stenosis
/ Stroke
/ Surgery
/ Switzerland - epidemiology
/ Thorax
/ Transcatheter Aortic Valve Replacement - adverse effects
/ Transcatheter Aortic Valve Replacement - instrumentation
/ Transcatheter Aortic Valve Replacement - methods
/ Transcatheter Aortic Valve Replacement - mortality
/ Treatment Outcome
/ United Kingdom - epidemiology
2019
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial
by
Walther, Thomas
, Conzelmann, Lars
, Heg, Dik
, Lanz, Jonas
, Windecker, Stephan
, Jüni, Peter
, Kerber, Sebastian
, Husser, Oliver
, Linke, Axel
, Stortecky, Stefan
, Thilo, Christian
, Prendergast, Bernard
, Kim, Won-Keun
, Joner, Michael
, Thiele, Holger
, Pilgrim, Thomas
, Hilker, Michael
, Möllmann, Helge
, Burgdorf, Christof
, Redwood, Simon
, Schymik, Gerhard
, Conradi, Lenard
in
Aged
/ Aged, 80 and over
/ Aortic stenosis
/ Aortic valve
/ Aortic Valve Stenosis - epidemiology
/ Aortic Valve Stenosis - mortality
/ Aortic Valve Stenosis - surgery
/ Balloon treatment
/ Bioprosthesis - adverse effects
/ Bleeding
/ Catheters
/ Cause of Death - trends
/ Clinical outcomes
/ Clinical trials
/ Confidence limits
/ Congestive heart failure
/ Coronary artery
/ Electrocardiography
/ Female
/ Germany - epidemiology
/ Heart attacks
/ Heart Valve Prosthesis - adverse effects
/ Heart valves
/ Humans
/ Kidneys
/ Male
/ Mortality risk
/ Netherlands - epidemiology
/ Patients
/ Postoperative Complications - epidemiology
/ Prostheses
/ Prosthesis Design
/ Randomization
/ Regurgitation
/ Risk
/ Safety
/ Secondary analysis
/ Severity of Illness Index
/ Stenosis
/ Stroke
/ Surgery
/ Switzerland - epidemiology
/ Thorax
/ Transcatheter Aortic Valve Replacement - adverse effects
/ Transcatheter Aortic Valve Replacement - instrumentation
/ Transcatheter Aortic Valve Replacement - methods
/ Transcatheter Aortic Valve Replacement - mortality
/ Treatment Outcome
/ United Kingdom - epidemiology
2019
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial
by
Walther, Thomas
, Conzelmann, Lars
, Heg, Dik
, Lanz, Jonas
, Windecker, Stephan
, Jüni, Peter
, Kerber, Sebastian
, Husser, Oliver
, Linke, Axel
, Stortecky, Stefan
, Thilo, Christian
, Prendergast, Bernard
, Kim, Won-Keun
, Joner, Michael
, Thiele, Holger
, Pilgrim, Thomas
, Hilker, Michael
, Möllmann, Helge
, Burgdorf, Christof
, Redwood, Simon
, Schymik, Gerhard
, Conradi, Lenard
in
Aged
/ Aged, 80 and over
/ Aortic stenosis
/ Aortic valve
/ Aortic Valve Stenosis - epidemiology
/ Aortic Valve Stenosis - mortality
/ Aortic Valve Stenosis - surgery
/ Balloon treatment
/ Bioprosthesis - adverse effects
/ Bleeding
/ Catheters
/ Cause of Death - trends
/ Clinical outcomes
/ Clinical trials
/ Confidence limits
/ Congestive heart failure
/ Coronary artery
/ Electrocardiography
/ Female
/ Germany - epidemiology
/ Heart attacks
/ Heart Valve Prosthesis - adverse effects
/ Heart valves
/ Humans
/ Kidneys
/ Male
/ Mortality risk
/ Netherlands - epidemiology
/ Patients
/ Postoperative Complications - epidemiology
/ Prostheses
/ Prosthesis Design
/ Randomization
/ Regurgitation
/ Risk
/ Safety
/ Secondary analysis
/ Severity of Illness Index
/ Stenosis
/ Stroke
/ Surgery
/ Switzerland - epidemiology
/ Thorax
/ Transcatheter Aortic Valve Replacement - adverse effects
/ Transcatheter Aortic Valve Replacement - instrumentation
/ Transcatheter Aortic Valve Replacement - methods
/ Transcatheter Aortic Valve Replacement - mortality
/ Treatment Outcome
/ United Kingdom - epidemiology
2019
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial
Journal Article
Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial
2019
Request Book From Autostore
and Choose the Collection Method
Overview
Transcatheter aortic valve replacement (TAVR) is the preferred treatment option for older patients with symptomatic severe aortic stenosis. Differences in the properties of available TAVR systems can affect clinical outcomes. Among patients undergoing TAVR, we compared the self-expanding ACURATE neo TAVR system with the balloon-expandable SAPIEN 3 TAVR system with regard to early safety and efficacy.
In this randomised non-inferiority trial, patients (aged ≥75 years) undergoing transfemoral TAVR for treatment of symptomatic severe aortic stenosis, and who were deemed to be at increased surgical risk, were recruited at 20 tertiary heart valve centres in Germany, the Netherlands, Switzerland, and the UK. Participants were randomly assigned (1:1) to receive treatment with the ACURATE neo or the SAPIEN 3 with a computer-based randomly permuted block scheme, stratified by study centre and Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) category. The primary composite safety and efficacy endpoint comprised all-cause death, any stroke, life-threatening or disabling bleeding, major vascular complications, coronary artery obstruction requiring intervention, acute kidney injury (stage 2 or 3), rehospitalisation for valve-related symptoms or congestive heart failure, valve-related dysfunction requiring repeat procedure, moderate or severe prosthetic valve regurgitation, or prosthetic valve stenosis within 30 days of the procedure. Endpoint assessors were masked to treatment allocation. Non-inferiority of ACURATE neo compared with SAPIEN 3 was assessed in the intention-to-treat population on the basis of a risk-difference margin of 7·7% for the primary composite endpoint, with a one-sided α of 0·05. This trial is registered with ClinicalTrials.gov (number NCT03011346) and is ongoing but not recruiting.
Between Feb 8, 2017, and Feb 2, 2019, up to 5132 patients were screened and 739 (mean age 82·8 years [SD 4·1]; median STS-PROM score 3·5% [IQR 2·6–5·0]) were enrolled. 30-day follow-up was available for 367 (99%) of 372 patients allocated to the ACURATE neo group, and 364 (99%) of 367 allocated to the SAPIEN 3 group. Within 30 days, the primary endpoint occurred in 87 (24%) patients in the ACURATE neo and in 60 (16%) in the SAPIEN 3 group; thus, non-inferiority of the ACURATE neo was not met (absolute risk difference 7·1% [upper 95% confidence limit 12·0%], p=0·42). Secondary analysis of the primary endpoint suggested superiority of the SAPIEN 3 device over the ACURATE neo device (95% CI for risk difference −1·3 to −12·9, p=0·0156). The ACURATE neo and SAPIEN 3 groups did not differ in incidence of all-cause death (nine patients [2%] vs three [1%]) and stroke (seven [2%] vs 11 [3%]); whereas acute kidney injury (11 [3%] vs three [1%]) and moderate or severe prosthetic aortic regurgitation (34 [9%] vs ten [3%]) were more common in the ACURATE neo group.
TAVR with the self-expanding ACURATE neo did not meet non-inferiority compared to the balloon-expandable SAPIEN 3 device in terms of early safety and clinical efficacy outcomes. An early composite safety and efficacy endpoint was useful in discriminating the performance of different TAVR systems.
Boston Scientific (USA).
Publisher
Elsevier Ltd,Elsevier Limited
Subject
/ Aortic Valve Stenosis - epidemiology
/ Aortic Valve Stenosis - mortality
/ Aortic Valve Stenosis - surgery
/ Bioprosthesis - adverse effects
/ Bleeding
/ Female
/ Heart Valve Prosthesis - adverse effects
/ Humans
/ Kidneys
/ Male
/ Patients
/ Postoperative Complications - epidemiology
/ Risk
/ Safety
/ Stenosis
/ Stroke
/ Surgery
/ Thorax
/ Transcatheter Aortic Valve Replacement - adverse effects
/ Transcatheter Aortic Valve Replacement - instrumentation
/ Transcatheter Aortic Valve Replacement - methods
This website uses cookies to ensure you get the best experience on our website.