Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
CT dose survey in adults: what sample size for what precision?
by
Van Muylem, Alain
, Tack, Denis
, Howarth, Nigel
, Gevenois, Pierre Alain
, Taylor, Stephen
in
Abdomen
/ Adult
/ Adults
/ Computed Tomography
/ Diagnostic Radiology
/ Female
/ Humans
/ Imaging
/ Internal Medicine
/ Interventional Radiology
/ Male
/ Medicine
/ Medicine & Public Health
/ Neuroradiology
/ Patients
/ Radiation
/ Radiation Dosage
/ Radiology
/ Reproducibility of Results
/ Retrospective Studies
/ Sample Size
/ Surveys and Questionnaires
/ Thorax
/ Tomography
/ Tomography, X-Ray Computed - methods
/ Tomography, X-Ray Computed - statistics & numerical data
/ Ultrasound
2017
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
CT dose survey in adults: what sample size for what precision?
by
Van Muylem, Alain
, Tack, Denis
, Howarth, Nigel
, Gevenois, Pierre Alain
, Taylor, Stephen
in
Abdomen
/ Adult
/ Adults
/ Computed Tomography
/ Diagnostic Radiology
/ Female
/ Humans
/ Imaging
/ Internal Medicine
/ Interventional Radiology
/ Male
/ Medicine
/ Medicine & Public Health
/ Neuroradiology
/ Patients
/ Radiation
/ Radiation Dosage
/ Radiology
/ Reproducibility of Results
/ Retrospective Studies
/ Sample Size
/ Surveys and Questionnaires
/ Thorax
/ Tomography
/ Tomography, X-Ray Computed - methods
/ Tomography, X-Ray Computed - statistics & numerical data
/ Ultrasound
2017
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
CT dose survey in adults: what sample size for what precision?
by
Van Muylem, Alain
, Tack, Denis
, Howarth, Nigel
, Gevenois, Pierre Alain
, Taylor, Stephen
in
Abdomen
/ Adult
/ Adults
/ Computed Tomography
/ Diagnostic Radiology
/ Female
/ Humans
/ Imaging
/ Internal Medicine
/ Interventional Radiology
/ Male
/ Medicine
/ Medicine & Public Health
/ Neuroradiology
/ Patients
/ Radiation
/ Radiation Dosage
/ Radiology
/ Reproducibility of Results
/ Retrospective Studies
/ Sample Size
/ Surveys and Questionnaires
/ Thorax
/ Tomography
/ Tomography, X-Ray Computed - methods
/ Tomography, X-Ray Computed - statistics & numerical data
/ Ultrasound
2017
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
CT dose survey in adults: what sample size for what precision?
Journal Article
CT dose survey in adults: what sample size for what precision?
2017
Request Book From Autostore
and Choose the Collection Method
Overview
Objectives
To determine variability of volume computed tomographic dose index (CTDIvol) and dose–length product (DLP) data, and propose a minimum sample size to achieve an expected precision.
Methods
CTDIvol and DLP values of 19,875 consecutive CT acquisitions of abdomen (7268), thorax (3805), lumbar spine (3161), cervical spine (1515) and head (4106) were collected in two centers. Their variabilities were investigated according to sample size (10 to 1000 acquisitions) and patient body weight categories (no weight selection, 67–73 kg and 60–80 kg). The 95 % confidence interval in percentage of their median (CI95/med) value was calculated for increasing sample sizes. We deduced the sample size that set a 95 % CI lower than 10 % of the median (CI95/med ≤ 10 %).
Results
Sample size ensuring CI95/med ≤ 10 %, ranged from 15 to 900 depending on the body region and the dose descriptor considered. In sample sizes recommended by regulatory authorities (i.e., from 10–20 patients), mean CTDIvol and DLP of one sample ranged from 0.50 to 2.00 times its actual value extracted from 2000 samples.
Conclusions
The sampling error in CTDIvol and DLP means is high in dose surveys based on small samples of patients. Sample size should be increased at least tenfold to decrease this variability.
Key Points
•
Variability of dose descriptors is high regardless of the body region
.
•
Variability of dose descriptors depends on weight selection and the region scanned
.
•
Larger samples would reduce sampling errors of radiation dose data in surveys
.
•
Totally or partially disabling AEC reduces dose variability and increases patient dose
.
•
Median values of dose descriptors depend on the body weight selection
.
This website uses cookies to ensure you get the best experience on our website.