MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Comparison of BiliCocoon phototherapy with overhead phototherapy in hyperbilirubinemic neonates. A randomized clinical trial
Comparison of BiliCocoon phototherapy with overhead phototherapy in hyperbilirubinemic neonates. A randomized clinical trial
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Comparison of BiliCocoon phototherapy with overhead phototherapy in hyperbilirubinemic neonates. A randomized clinical trial
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Comparison of BiliCocoon phototherapy with overhead phototherapy in hyperbilirubinemic neonates. A randomized clinical trial
Comparison of BiliCocoon phototherapy with overhead phototherapy in hyperbilirubinemic neonates. A randomized clinical trial

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Comparison of BiliCocoon phototherapy with overhead phototherapy in hyperbilirubinemic neonates. A randomized clinical trial
Comparison of BiliCocoon phototherapy with overhead phototherapy in hyperbilirubinemic neonates. A randomized clinical trial
Journal Article

Comparison of BiliCocoon phototherapy with overhead phototherapy in hyperbilirubinemic neonates. A randomized clinical trial

2025
Request Book From Autostore and Choose the Collection Method
Overview
Background Around 2–6% of term or late preterm neonates receive phototherapy for hyperbilirubinemia. Standard treatment today is overhead phototherapy. A new device has been developed, the BiliCocoon, where the neonates are “wrapped” presumably making them more comfortable. The aim was to compare the efficacy and performance of the BiliCocoon with overhead LED phototherapy. Methods A randomized open-label multicenter trial in three Danish neonatal units. Healthy hyperbilirubinemic neonates, gestational age ≥33 weeks and postnatal age 24 h to 14 days were randomized to 24 hours’ of treatment with BiliCocoon or overhead blue LED phototherapy with an equal level of irradiance. A mixed effect model with random effect by center was used to compare the percentage decrease in total serum bilirubin (TSB) between the treatments. Results Totally 83 neonates were included. Mean TSB reduction in the BiliCocoon group ( N  = 42), adjusted for baseline TSB, was significantly lower than in the overhead LED group ( N  = 41), 29% vs. 38% ( p -value < 0.01). Overall difference in temperature by treatment (BiliCocoon vs overhead) was 0.70 [0.37; 1.02] °C, p -value < 0.01. Conclusion Bilirubin reducing efficacy of BiliCocoon was lower than that of overhead phototherapy, but it was sufficient for nearly all neonates during 24 hours of treatment. Impact The BiliCocoon has a bilirubin reducing efficacy, sufficient for almost all neonates during 24 hours of phototherapy. The BiliCocoon does not have an equal bilirubin reducing efficacy as overhead phototherapy. The duration of light exposure was longer for the neonates treated in the BiliCocoon. A few neonates can be exclusively breastfed in the BiliCocoon throughout the treatment. The reason for stopping breastfeeding in the BiliCocoon was most often, that the neonates developed hyperthermia.