Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Comparison of Accuracy of Current Ten Intraoral Scanners
by
Sanohkan, Sasiwimol
, Rokaya, Dinesh
, Amornvit, Pokpong
in
Accuracy
/ Beryl
/ Computer-Aided Design
/ Dentistry
/ Diagnosis, Oral - instrumentation
/ Equipment and supplies
/ High resolution
/ Humans
/ Image processing
/ Imaging, Three-Dimensional - instrumentation
/ Kolmogorov-Smirnov test
/ Laboratories
/ Lithography
/ Models, Dental
/ Prostheses
/ Scanners
/ Scanning
/ Software
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Comparison of Accuracy of Current Ten Intraoral Scanners
by
Sanohkan, Sasiwimol
, Rokaya, Dinesh
, Amornvit, Pokpong
in
Accuracy
/ Beryl
/ Computer-Aided Design
/ Dentistry
/ Diagnosis, Oral - instrumentation
/ Equipment and supplies
/ High resolution
/ Humans
/ Image processing
/ Imaging, Three-Dimensional - instrumentation
/ Kolmogorov-Smirnov test
/ Laboratories
/ Lithography
/ Models, Dental
/ Prostheses
/ Scanners
/ Scanning
/ Software
2021
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Comparison of Accuracy of Current Ten Intraoral Scanners
by
Sanohkan, Sasiwimol
, Rokaya, Dinesh
, Amornvit, Pokpong
in
Accuracy
/ Beryl
/ Computer-Aided Design
/ Dentistry
/ Diagnosis, Oral - instrumentation
/ Equipment and supplies
/ High resolution
/ Humans
/ Image processing
/ Imaging, Three-Dimensional - instrumentation
/ Kolmogorov-Smirnov test
/ Laboratories
/ Lithography
/ Models, Dental
/ Prostheses
/ Scanners
/ Scanning
/ Software
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Journal Article
Comparison of Accuracy of Current Ten Intraoral Scanners
2021
Request Book From Autostore
and Choose the Collection Method
Overview
There have been various developments in intraoral 3D scanning technology. This study is aimed at investigating the accuracy of 10 scanners developed from 2015 to 2020. A maxillary dental model with reference points was printed from Form 2 (FormLabs, Somerville, MA, USA). The model was scanned 5 times with each intraoral scanner (IOS); Trios 3 (normal and high-resolution mode); Trios 4 (normal and high-resolution mode) (3Shape Trios A/S, Copenhagen, Denmark); iTero Element, iTero 2, and iTero 5D Element (Align Technologies, San Jose, California, USA); Dental Wings (Dental Wings, Montreal QC, Canada); Panda 2 (Pengtum Technologies, Shanghai, China); Medit i500 (Medit Corp. Seoul, South Korea); Planmeca Emerald™ (Planmeca, Helsinki, Finland); and Aoralscan (Shining 3D Tech. Co., Ltd., Hangzhou, China). After the scan, the 3D scanned stereolithography files were created. The various distances were measured five times in X, Y, Z, and XY axes of various scans and with a vernier caliper (control) and from the Rhinoceros software. The data were analyzed using SPSS 18. Test for the normality of the various measurement data were done using Kolmogorov-Smirnov test. The trueness and precision of the measurements were compared among the various scans using the Kruskal-Wallis test. The significance was considered at P<0.05. The trueness of the intraoral scans was analyzed by comparing the measurements from the control. Precision was tested through the measurements of repeated scans. It showed that more the distance is less the accuracy for all scanners. In all studied scanners, the trueness varied but precision was favorably similar. Diagonal scanning showed less accuracy for all the scanners. Hence, when scanning the full arch, the dentist needs to take more caution and good scan pattern. Trios series showed the best scan results compared to other scanners.