MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Ease of use of tobramycin inhalation powder compared with nebulized tobramycin and colistimethate sodium: a crossover study in cystic fibrosis patients with pulmonary Pseudomonas aeruginosa infection
Ease of use of tobramycin inhalation powder compared with nebulized tobramycin and colistimethate sodium: a crossover study in cystic fibrosis patients with pulmonary Pseudomonas aeruginosa infection
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Ease of use of tobramycin inhalation powder compared with nebulized tobramycin and colistimethate sodium: a crossover study in cystic fibrosis patients with pulmonary Pseudomonas aeruginosa infection
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Ease of use of tobramycin inhalation powder compared with nebulized tobramycin and colistimethate sodium: a crossover study in cystic fibrosis patients with pulmonary Pseudomonas aeruginosa infection
Ease of use of tobramycin inhalation powder compared with nebulized tobramycin and colistimethate sodium: a crossover study in cystic fibrosis patients with pulmonary Pseudomonas aeruginosa infection

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Ease of use of tobramycin inhalation powder compared with nebulized tobramycin and colistimethate sodium: a crossover study in cystic fibrosis patients with pulmonary Pseudomonas aeruginosa infection
Ease of use of tobramycin inhalation powder compared with nebulized tobramycin and colistimethate sodium: a crossover study in cystic fibrosis patients with pulmonary Pseudomonas aeruginosa infection
Journal Article

Ease of use of tobramycin inhalation powder compared with nebulized tobramycin and colistimethate sodium: a crossover study in cystic fibrosis patients with pulmonary Pseudomonas aeruginosa infection

2017
Request Book From Autostore and Choose the Collection Method
Overview
Background: This study assessed the ease of use of tobramycin inhalation powder (TIP) administered via T-326 inhaler versus tobramycin inhalation solution (TIS) and colistimethate sodium (COLI), both administered via nebulizers, for the treatment of chronic pulmonary Pseudomonas aeruginosa infection in patients with cystic fibrosis (CF). Methods: A real-world, open-label, crossover, interventional phase IV study was conducted in CF patients aged ⩾6 years with forced expiratory volume in 1 second (FEV1) ⩾25% to ⩽90% predicted. Patients were assigned to one of the three treatment arms in Cycle 1; all patients received TIP in Cycle 2. Each cycle consisted of 28 days on and 28 days off the treatment. Results: A total of 60 patients [mean (standard deviation) age, 27.6 (8.4) years] were allocated to three treatment arms [TIS/TIP (n = 14); COLI/TIP (n = 28); TIP/TIP (n = 18)] in Cycle 1. The mean total administration time, which included device setup and cleaning, in Cycle 1 versus Cycle 2 for TIS/TIP, COLI/TIP, and TIP/TIP arms were 37.0 versus 5.0 min, 16.4 versus 3.8 min, and 4.2 versus 3.4 min, respectively. The difference in mean total administration time was significantly shorter in Cycle 2 than in Cycle 1 for TIS/TIP (p = 0.0112) and COLI/TIP (p = 0.0016) arms. Overall, 12 patients were found to have contaminated devices across the two treatment cycles. In the TIP/TIP arm, no contamination of the T-326 inhaler was observed in either cycle. Treatment satisfaction, assessed by the Treatment Satisfaction Questionnaire for Medication and ACCEPT® questionnaire, was better overall for TIP compared with TIS and COLI. There were no unexpected adverse events and most were mild or moderate in intensity. Conclusion: The T-326 inhaler used to deliver TIP was easy to use, required shorter total administration time, and was much less frequently contaminated than the nebulizers. The safety findings observed for TIP were generally consistent with its established safety profile.