MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Development of a log file analysis tool for proton patient QA, system performance tracking, and delivered dose reconstruction
Development of a log file analysis tool for proton patient QA, system performance tracking, and delivered dose reconstruction
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Development of a log file analysis tool for proton patient QA, system performance tracking, and delivered dose reconstruction
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Development of a log file analysis tool for proton patient QA, system performance tracking, and delivered dose reconstruction
Development of a log file analysis tool for proton patient QA, system performance tracking, and delivered dose reconstruction

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Development of a log file analysis tool for proton patient QA, system performance tracking, and delivered dose reconstruction
Development of a log file analysis tool for proton patient QA, system performance tracking, and delivered dose reconstruction
Journal Article

Development of a log file analysis tool for proton patient QA, system performance tracking, and delivered dose reconstruction

2023
Request Book From Autostore and Choose the Collection Method
Overview
Purpose/Objective(s) To describe a log file–based patient‐specific quality assurance (QA) method and develop an in‐house tool for system performance tracking and dose reconstruction in pencil‐beam scanning proton therapy that can be used for pre‐treatment plan review. Materials/Methods The software extracts beam‐specific information from the treatment delivery log file and automatically compares the monitor units (MU), lateral position, and size of each spot against the intended values in the treatment plan to identify any discrepancies in the beam delivery. The software has been used to analyze 992 patients, 2004 plans, 4865 fields, and more than 32 million proton spots from 2016 to 2021. The composite doses of 10 craniospinal irradiation (CSI) plans were reconstructed based on the delivered spots and compared with the original plans as an offline plan review method. Results Over the course of 6 years, the proton delivery system has proved stable in delivering patient QA fields with proton energies of 69.4–221.3 MeV and an MU range of 0.003–1.473 MU per spot. The planned mean and standard deviation (SD) of the energy and spot MU were 114.4 ± 26.4 MeV and 0.010 ± 0.009 MU, respectively. The mean and SD of the differences in MU and position between the delivered and planned spots were 9.56 × 10−8 ± 2.0 × 10−4 MU and 0.029/−0.007 ± 0.049/0.044 mm on the X/Y‐axis for random differences and 0.005/0.125 ± 0.189/0.175 mm on the X/Y‐axis for systematic differences. The mean and SD of the difference between the commissioning and delivered spot sizes were 0.086/0.089 ± 0.131/0.166 mm on the X/Y‐axis. Conclusion A tool has been developed to extract crucial information about the performance of the proton delivery and monitor system and provide a dose reconstruction based on delivered spots for quality improvement. Each patient's plan was verified before treatment to ensure accurate and safe delivery within the delivery tolerance of the machine.