Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Development and Evaluation of Deep Learning-Based Reconstruction Using Preclinical 7T Magnetic Resonance Imaging
by
Takuma Kobayashi
, Junpei Ueda
, Naoki Tsuji
, Shigeyoshi Saito
in
Accuracy
/ Biology (General)
/ Brain research
/ Chemistry
/ Deep learning
/ deep learning-based reconstruction
/ Engineering (General). Civil engineering (General)
/ Laboratory animals
/ Magnetic resonance imaging
/ Medical imaging equipment
/ Neural networks
/ number of excitations
/ Physics
/ preclinical 7T MRI
/ QC1-999
/ QD1-999
/ QH301-705.5
/ Quality improvement
/ Signal to noise ratio
/ T
/ TA1-2040
/ Technology
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Development and Evaluation of Deep Learning-Based Reconstruction Using Preclinical 7T Magnetic Resonance Imaging
by
Takuma Kobayashi
, Junpei Ueda
, Naoki Tsuji
, Shigeyoshi Saito
in
Accuracy
/ Biology (General)
/ Brain research
/ Chemistry
/ Deep learning
/ deep learning-based reconstruction
/ Engineering (General). Civil engineering (General)
/ Laboratory animals
/ Magnetic resonance imaging
/ Medical imaging equipment
/ Neural networks
/ number of excitations
/ Physics
/ preclinical 7T MRI
/ QC1-999
/ QD1-999
/ QH301-705.5
/ Quality improvement
/ Signal to noise ratio
/ T
/ TA1-2040
/ Technology
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Development and Evaluation of Deep Learning-Based Reconstruction Using Preclinical 7T Magnetic Resonance Imaging
by
Takuma Kobayashi
, Junpei Ueda
, Naoki Tsuji
, Shigeyoshi Saito
in
Accuracy
/ Biology (General)
/ Brain research
/ Chemistry
/ Deep learning
/ deep learning-based reconstruction
/ Engineering (General). Civil engineering (General)
/ Laboratory animals
/ Magnetic resonance imaging
/ Medical imaging equipment
/ Neural networks
/ number of excitations
/ Physics
/ preclinical 7T MRI
/ QC1-999
/ QD1-999
/ QH301-705.5
/ Quality improvement
/ Signal to noise ratio
/ T
/ TA1-2040
/ Technology
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Development and Evaluation of Deep Learning-Based Reconstruction Using Preclinical 7T Magnetic Resonance Imaging
Journal Article
Development and Evaluation of Deep Learning-Based Reconstruction Using Preclinical 7T Magnetic Resonance Imaging
2023
Request Book From Autostore
and Choose the Collection Method
Overview
This study investigated a method for improving the quality of images with a low number of excitations (NEXs) based on deep learning using T2-weighted magnetic resonance imaging (MRI) of the heads of normal Wistar rats to achieve higher image quality and a shorter acquisition time. A 7T MRI was used to acquire T2-weighted images of the whole brain with NEXs = 2, 4, 8, and 12. As a preprocessing step, non-rigid registration of the acquired low NEX images (NEXs = 2, 4, 8) and NEXs = 12 images was performed. A residual dense network (RDN) was used for training. A low NEX image was used as the input to the RDN, and the NEX12 image was used as the correct image. For quantitative evaluation, we measured the signal-to-noise ratio (SNR), peak SNR, and structural similarity index measure of the original image and the image obtained by RDN. The NEX2 results are presented as an example. The SNR of the cortex was 10.4 for NEX2, whereas the SNR of the image reconstructed with RDN for NEX2 was 32.1. (The SNR NEX12 was 19.6) In addition, the PSNR in NEX2 was significantly increased to 35.4 ± 2.0 compared to the input image and to 37.6 ± 2.9 compared to the reconstructed image (p = 0.05). The SSIM in NEX2 was 0.78 ± 0.05 compared to the input image and 0.91 ± 0.05 compared to the reconstructed image (p = 0.0003). Furthermore, NEX2 succeeded in reducing the shooting time by 83%. Therefore, in preclinical 7T MRI, supervised learning between the NEXs using RDNs can potentially improve the image quality of low NEX images and shorten the acquisition time.
Publisher
MDPI AG
This website uses cookies to ensure you get the best experience on our website.