Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study
by
Pooni, Rubin
, Senf, Brian
, Patton, Susana R
, El Youssef, Joseph
, Riddell, Michael C
, Clements, Mark A
, Castle, Jessica R
, Reddy, Ravi Kondama
, Jacobs, Peter G
, Dassau, Eyal
, Rickels, Michael R
, Zaharieva, Dessi P
, Doyle III, Francis J
in
Accuracy
/ Aerobics
/ Automation
/ Control algorithms
/ Diabetes
/ Drug dosages
/ Exercise
/ Fitness equipment
/ Glucose
/ Hypoglycemia
/ Insulin
/ Metabolism
/ Original Paper
/ Physical fitness
/ Wearable computers
2018
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study
by
Pooni, Rubin
, Senf, Brian
, Patton, Susana R
, El Youssef, Joseph
, Riddell, Michael C
, Clements, Mark A
, Castle, Jessica R
, Reddy, Ravi Kondama
, Jacobs, Peter G
, Dassau, Eyal
, Rickels, Michael R
, Zaharieva, Dessi P
, Doyle III, Francis J
in
Accuracy
/ Aerobics
/ Automation
/ Control algorithms
/ Diabetes
/ Drug dosages
/ Exercise
/ Fitness equipment
/ Glucose
/ Hypoglycemia
/ Insulin
/ Metabolism
/ Original Paper
/ Physical fitness
/ Wearable computers
2018
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study
by
Pooni, Rubin
, Senf, Brian
, Patton, Susana R
, El Youssef, Joseph
, Riddell, Michael C
, Clements, Mark A
, Castle, Jessica R
, Reddy, Ravi Kondama
, Jacobs, Peter G
, Dassau, Eyal
, Rickels, Michael R
, Zaharieva, Dessi P
, Doyle III, Francis J
in
Accuracy
/ Aerobics
/ Automation
/ Control algorithms
/ Diabetes
/ Drug dosages
/ Exercise
/ Fitness equipment
/ Glucose
/ Hypoglycemia
/ Insulin
/ Metabolism
/ Original Paper
/ Physical fitness
/ Wearable computers
2018
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study
Journal Article
Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study
2018
Request Book From Autostore
and Choose the Collection Method
Overview
Wrist-worn activity monitors are often used to monitor heart rate (HR) and energy expenditure (EE) in a variety of settings including more recently in medical applications. The use of real-time physiological signals to inform medical systems including drug delivery systems and decision support systems will depend on the accuracy of the signals being measured, including accuracy of HR and EE. Prior studies assessed accuracy of wearables only during steady-state aerobic exercise.
The objective of this study was to validate the accuracy of both HR and EE for 2 common wrist-worn devices during a variety of dynamic activities that represent various physical activities associated with daily living including structured exercise.
We assessed the accuracy of both HR and EE for two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) during dynamic activities. Over a 2-day period, 20 healthy adults (age: mean 27.5 [SD 6.0] years; body mass index: mean 22.5 [SD 2.3] kg/m
; 11 females) performed a maximal oxygen uptake test, free-weight resistance circuit, interval training session, and activities of daily living. Validity was assessed using an HR chest strap (Polar) and portable indirect calorimetry (Cosmed). Accuracy of the commercial wearables versus research-grade standards was determined using Bland-Altman analysis, correlational analysis, and error bias.
Fitbit and Garmin were reasonably accurate at measuring HR but with an overall negative bias. There was more error observed during high-intensity activities when there was a lack of repetitive wrist motion and when the exercise mode indicator was not used. The Garmin estimated HR with a mean relative error (RE, %) of -3.3% (SD 16.7), whereas Fitbit estimated HR with an RE of -4.7% (SD 19.6) across all activities. The highest error was observed during high-intensity intervals on bike (Fitbit: -11.4% [SD 35.7]; Garmin: -14.3% [SD 20.5]) and lowest error during high-intensity intervals on treadmill (Fitbit: -1.7% [SD 11.5]; Garmin: -0.5% [SD 9.4]). Fitbit and Garmin EE estimates differed significantly, with Garmin having less negative bias (Fitbit: -19.3% [SD 28.9], Garmin: -1.6% [SD 30.6], P<.001) across all activities, and with both correlating poorly with indirect calorimetry measures.
Two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) show good HR accuracy, with a small negative bias, and reasonable EE estimates during low to moderate-intensity exercise and during a variety of common daily activities and exercise. Accuracy was compromised markedly when the activity indicator was not used on the watch or when activities involving less wrist motion such as cycle ergometry were done.
Publisher
JMIR Publications
Subject
This website uses cookies to ensure you get the best experience on our website.