MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Derivation of a pragmatic three-view protocol for point-of-care transesophageal echocardiography in the cardiovascular ICU: a real-world cohort study
Derivation of a pragmatic three-view protocol for point-of-care transesophageal echocardiography in the cardiovascular ICU: a real-world cohort study
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Derivation of a pragmatic three-view protocol for point-of-care transesophageal echocardiography in the cardiovascular ICU: a real-world cohort study
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Derivation of a pragmatic three-view protocol for point-of-care transesophageal echocardiography in the cardiovascular ICU: a real-world cohort study
Derivation of a pragmatic three-view protocol for point-of-care transesophageal echocardiography in the cardiovascular ICU: a real-world cohort study

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Derivation of a pragmatic three-view protocol for point-of-care transesophageal echocardiography in the cardiovascular ICU: a real-world cohort study
Derivation of a pragmatic three-view protocol for point-of-care transesophageal echocardiography in the cardiovascular ICU: a real-world cohort study
Journal Article

Derivation of a pragmatic three-view protocol for point-of-care transesophageal echocardiography in the cardiovascular ICU: a real-world cohort study

2026
Request Book From Autostore and Choose the Collection Method
Overview
Background Rapid identification of the cause of hemodynamic instability is essential in the cardiovascular intensive care unit (CV-ICU), and transesophageal echocardiography provides superior diagnostic image quality compared with transthoracic echocardiography in this setting. However, point-of-care transesophageal echocardiography (POCUS-TEE) is not routinely used, partly because of perceived training barriers. We therefore sought to summarize the etiologies of hemodynamic instability in the CV-ICU and to identify a pragmatic minimal set of TEE views required for their diagnosis. Methods This single-center retrospective study evaluated consecutive adult cardiovascular ICU admissions over five years. All POCUS-TEE examinations were performed as part of routine clinical care at the discretion of the treating team. Examinations in patients with hemodynamic instability were analyzed to identify the “first informative view” supporting the diagnosis. A cumulative coverage analysis was performed to derive a minimal-view set. Inter-rater reproducibility was assessed for view acquisition and management decisions. Results Among 6,898 admissions, POCUS-TEE was performed in 353 examinations (5.1%), predominantly in patients with higher severity scores compared to those without TEE. In preoperative stable patients ( n  = 37), POCUS-TEE altered planned surgery in 6 patients (16.2%). In postoperative stable patients ( n  = 101), management changes included optimization of mechanical support and anticoagulation. In postoperative-unstable examinations ( n  = 238), 79.4% prompted procedural interventions. A derived minimal three-view set (mid-esophageal bicaval, mid-esophageal four-chamber, and transgastric mid-short-axis) achieved 92.4% diagnostic coverage in unstable examinations. While the specific view acting as the first diagnostic window varied due to acquisition sequence (κ 0.06–0.11), the core three-view set was highly reproducible across raters (Jaccard similarity coefficient 0.60), and agreement on management decisions was moderate. No procedure-related complications were observed during bedside POCUS-TEE. Conclusions POCUS-TEE frequently drives urgent interventions in postoperative hemodynamic instability. Although the sequence of diagnostic capture is operator-dependent, a simple three-view protocol provides > 90% diagnostic coverage. This derivation supports a physiology-based, limited-view approach for training, early competency development, and resuscitation in cardiovascular critical care.