Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Efficacy of Wearable Single-Lead ECG Monitoring during Exercise Stress Testing: A Comparative Study
by
Choi, Hyo-In
, Lee, Young-Shin
, Lee, Jong-Young
, Lee, Seung Jae
, Choi, Jong Doo
, Kim, GyungChul
in
Adult
/ Aged
/ Anaerobic threshold
/ biomedical technology
/ Cardiac arrhythmia
/ Cardiac patients
/ Cardiovascular disease
/ Care and treatment
/ Clinical outcomes
/ Comparative analysis
/ Coronary vessels
/ Diabetes
/ Electrocardiogram
/ Electrocardiography
/ Electrocardiography - instrumentation
/ Electrocardiography - methods
/ Equipment and supplies
/ Exercise - physiology
/ Exercise intensity
/ exercise test
/ Exercise Test - instrumentation
/ Exercise Test - methods
/ Exercise tests
/ Female
/ Fitness equipment
/ Heart attacks
/ Heart beat
/ Heart failure
/ Heart rate
/ Heart Rate - physiology
/ Humans
/ Hypertension
/ Male
/ Measurement
/ Metabolism
/ Middle Aged
/ Patients
/ Physiology
/ Rehabilitation
/ Software
/ Testing
/ Wearable Electronic Devices
/ wearable technology
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Efficacy of Wearable Single-Lead ECG Monitoring during Exercise Stress Testing: A Comparative Study
by
Choi, Hyo-In
, Lee, Young-Shin
, Lee, Jong-Young
, Lee, Seung Jae
, Choi, Jong Doo
, Kim, GyungChul
in
Adult
/ Aged
/ Anaerobic threshold
/ biomedical technology
/ Cardiac arrhythmia
/ Cardiac patients
/ Cardiovascular disease
/ Care and treatment
/ Clinical outcomes
/ Comparative analysis
/ Coronary vessels
/ Diabetes
/ Electrocardiogram
/ Electrocardiography
/ Electrocardiography - instrumentation
/ Electrocardiography - methods
/ Equipment and supplies
/ Exercise - physiology
/ Exercise intensity
/ exercise test
/ Exercise Test - instrumentation
/ Exercise Test - methods
/ Exercise tests
/ Female
/ Fitness equipment
/ Heart attacks
/ Heart beat
/ Heart failure
/ Heart rate
/ Heart Rate - physiology
/ Humans
/ Hypertension
/ Male
/ Measurement
/ Metabolism
/ Middle Aged
/ Patients
/ Physiology
/ Rehabilitation
/ Software
/ Testing
/ Wearable Electronic Devices
/ wearable technology
2024
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Efficacy of Wearable Single-Lead ECG Monitoring during Exercise Stress Testing: A Comparative Study
by
Choi, Hyo-In
, Lee, Young-Shin
, Lee, Jong-Young
, Lee, Seung Jae
, Choi, Jong Doo
, Kim, GyungChul
in
Adult
/ Aged
/ Anaerobic threshold
/ biomedical technology
/ Cardiac arrhythmia
/ Cardiac patients
/ Cardiovascular disease
/ Care and treatment
/ Clinical outcomes
/ Comparative analysis
/ Coronary vessels
/ Diabetes
/ Electrocardiogram
/ Electrocardiography
/ Electrocardiography - instrumentation
/ Electrocardiography - methods
/ Equipment and supplies
/ Exercise - physiology
/ Exercise intensity
/ exercise test
/ Exercise Test - instrumentation
/ Exercise Test - methods
/ Exercise tests
/ Female
/ Fitness equipment
/ Heart attacks
/ Heart beat
/ Heart failure
/ Heart rate
/ Heart Rate - physiology
/ Humans
/ Hypertension
/ Male
/ Measurement
/ Metabolism
/ Middle Aged
/ Patients
/ Physiology
/ Rehabilitation
/ Software
/ Testing
/ Wearable Electronic Devices
/ wearable technology
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Efficacy of Wearable Single-Lead ECG Monitoring during Exercise Stress Testing: A Comparative Study
Journal Article
Efficacy of Wearable Single-Lead ECG Monitoring during Exercise Stress Testing: A Comparative Study
2024
Request Book From Autostore
and Choose the Collection Method
Overview
Background and Objectives: Few comparative studies have evaluated wearable single-lead electrocardiogram (ECG) devices and standard multi-lead ECG devices during exercise testing. This study aimed to validate the accuracy of a wearable single-lead ECG monitor for recording heart rate (HR) metrics during graded exercise tests (GXTs). Methods: A cohort of 50 patients at a tertiary hospital underwent GXT while simultaneously being equipped with wearable single- and conventional multi-lead ECGs. The concordance between these modalities was quantified using the intraclass correlation coefficient and Bland–Altman plot analysis. Results: The minimum and average HR readings between the devices were generally consistent. Parameters such as ventricular ectopic beats and supraventricular ectopic beats showed strong agreement. However, the agreement for the Total QRS and Maximum RR was not sufficient. HR measurements across different stages of the exercise test showed sufficient agreement. Although not statistically significant, the standard multi-lead ECG devices exhibited higher noise levels compared to the wearable single-lead ECG devices. Conclusions: Wearable single-lead ECG devices can reliably monitor HR and detect abnormal beats across a spectrum of exercise intensities, offering a viable alternative to traditional multi-lead systems.
Publisher
MDPI AG,MDPI
Subject
This website uses cookies to ensure you get the best experience on our website.