MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Adaptive Control-based frequency control strategy for PV/ DEG/ battery power system during islanding conditions
Adaptive Control-based frequency control strategy for PV/ DEG/ battery power system during islanding conditions
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Adaptive Control-based frequency control strategy for PV/ DEG/ battery power system during islanding conditions
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Adaptive Control-based frequency control strategy for PV/ DEG/ battery power system during islanding conditions
Adaptive Control-based frequency control strategy for PV/ DEG/ battery power system during islanding conditions

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Adaptive Control-based frequency control strategy for PV/ DEG/ battery power system during islanding conditions
Adaptive Control-based frequency control strategy for PV/ DEG/ battery power system during islanding conditions
Journal Article

Adaptive Control-based frequency control strategy for PV/ DEG/ battery power system during islanding conditions

2025
Request Book From Autostore and Choose the Collection Method
Overview
The concept of Islanded Hybrid Power System (IHPS) has attracted considerable interest lately, especially for energizing remote or energy-poor locations. IHPS are more dependable and cost-effective alternatives to systems using only one energy source when properly constructed. IHPS configuration, including Diesel Engine Generator (DEG), Photovoltaic (PV) systems, and Battery Storage (BATT) elements, are desirable for islanded systems about price and dependability. IHPS mostly use Renewable Energy Sources (RES) for power production, which is variable. Consequently, these variations often make it difficult for traditional control systems to maximize efficiency across various operating environments. The current research discusses the requirement for more effective frequency control in IHPS by suggesting a Model Reference Adaptive Control-Fuzzy Proportional Integral based Whale Optimization Algorithm (MRAC-FPI-WOA) controller. The proposed controller can efficiently manage a range of disturbances by dynamically adjusting its control techniques. The current research conducts an evaluation study comparing the effectiveness of the suggested MRAC-FPI-WOA controller against FPI-WOA, PI-WOA, and PI-PSO controllers. The key evaluation criteria are the ability to maintain stability in frequency within the IHPS and the effectiveness of power production in the overall system. The results demonstrate the superior performance of the MRAC-FPI-WOA controller across diverse operational scenarios. Notably, during a three-phase fault at Bus2, the MRAC-FPI-WOA controller achieves significant performance enhancements over the PI-PSO controller, with reductions of 59.05% in maximum overshoot (% ), 72.83% in maximum undershoot (% ), 32.07% in settling time ( ), and 34.81% in the integral of time-weighted absolute error (ITAE). A similar trend is observed during a three-phase fault at the tie-line, where the MRAC-FPI-WOA controller yields improvements of 57.47% in % , 79.36% in % , 40.9% in , and 78.08% in ITAE. Furthermore, the controller exhibits exceptional dynamic responsiveness to ramp variations in solar radiation, substantially reducing % by 96.72%, % by 95.24%, by 22.79%, and ITAE by 89.69%. Additionally, it demonstrates robust adaptability to random solar radiation fluctuations, consistently optimizing transient response with reductions of 96.63% in % , 99.58% in % , 22.07% in , and 95.23% in ITAE.